Home › Engine / Hybrid System › 2AR-FE INTAKE / EXHAUST › INTAKE MANIFOLD
RM30B0U _51 Engine / Hybrid System _009090 2AR-FE INTAKE / EXHAUST _0049676 INTAKE MANIFOLD A

2AR-FE INTAKE / EXHAUST  INTAKE MANIFOLD  INSTALLATION  


PROCEDURE

Hide 2.INSTALL PURGE LINE HOSE

a.

Install the purge line hose to the intake manifold, and slide the clamp to secure it.


b.

Connect the purge line hose to the clamp.


Hide 3.INSTALL CHECK VALVE

a.

Install the 2 vacuum hoses to the check valve.


b.

Connect the 2 vacuum hoses to the intake manifold to install the check valve.


c.
A196051
0.708,1.813 0.885,1.813 0.885,1.813 1.281,1.417 true 0.531,1.74 0.698,1.896 0.167,0.156 10 *1
*1 Black


Check that the check valve is installed as shown in the illustration.


Hide 4.INSTALL UNION TO CONNECTOR TUBE HOSE

a.

Install the union to connector tube hose to the intake manifold, and slide the clamp to secure it.


Hide 5.INSTALL INTAKE MANIFOLD

a.

Install the 2 vacuum hoses to the intake manifold.


b.
A293722
0.052,0.052 0.25,0.229 0.198,0.177 10 *a
*a Condition: Closed


Close the tumble control valves.

NOTICE:

The valves may be damaged if they are not closed before installing the intake manifold.


HINT:

Connect the battery to the terminals of the actuator and operate the motor to close the valves.

Click hereEngine / Hybrid System>2AR-FE INTAKE / EXHAUST>INTAKE SYSTEM>ON-VEHICLE INSPECTION



c.
A196819

Install a new gasket to the intake manifold.


d.
A293747
1.875,1.156 2.031,1.354 0.156,0.198 10 1 1.156,0.052 1.313,0.25 0.156,0.198 10 2 2.615,0.031 2.771,0.229 0.156,0.198 10 3 3.24,0.646 3.396,0.844 0.156,0.198 10 4 0.542,0.594 0.698,0.792 0.156,0.198 10 5 0.729,1.844 0.885,2.042 0.156,0.198 10 6

Install the intake manifold with the 6 bolts and tighten the bolts in the sequence shown in the illustration.

Torque:
21 N*m (214 kgf*cm, 15 ft.*lbf)


Hide 6.CONNECT NO. 2 PCV HOSE

a.

Connect the No. 2 PCV hose to the intake manifold, and slide the clamp to secure it.


Hide 7.CONNECT WIRE HARNESS

a.

Attach the clamp and connect the wire harness.


b.

Install the bracket with the bolt.

Torque:
10 N*m (102 kgf*cm, 7 ft.*lbf)


c.

Connect the intake air control actuator connector.


d.

Install the wire harness clamp bracket with the 2 bolts.

Torque:
10 N*m (102 kgf*cm, 7 ft.*lbf)


e.

Attach the 2 clamps.


f.

Connect the 2 vacuum hoses and connector and attach the clamp to the vacuum switching valve.


Hide 8.CONNECT HEATER HOSE

a.

Connect the outlet heater water hose to the heater radiator unit, and slide the clamp to secure it.


b.

Connect the inlet heater water hose to the heater radiator unit, and slide the clamp to secure it.


Hide 9.INSTALL NO. 1 HOSE TO HOSE TUBE

a.

Install the No. 1 hose to hose tube with the 2 nuts.

Torque:
5.4 N*m (55 kgf*cm, 48 in.*lbf)


b.

Connect the 2 hoses, and slide the 2 clamps to secure the hoses.


Hide 10.INSTALL OUTER COWL TOP PANEL SUB-ASSEMBLY

a.

Install the outer cowl top panel sub-assembly with the 13 bolts.

Torque:
7.0 N*m (71 kgf*cm, 62 in.*lbf)


b.

Attach the clamp to the outer cowl top panel sub-assembly.


Hide 11.INSTALL WINDSHIELD WIPER MOTOR ASSEMBLY

Hide 12.INSTALL THROTTLE WITH MOTOR BODY ASSEMBLY

Hide 13.INSTALL FUEL DELIVERY PIPE