Home › Engine / Hybrid System › 2AR-FE INTAKE / EXHAUST › EXHAUST PIPE
RM30B0U _51 Engine / Hybrid System _009090 2AR-FE INTAKE / EXHAUST _0049680 EXHAUST PIPE A

2AR-FE INTAKE / EXHAUST  EXHAUST PIPE  REMOVAL  


CAUTION / NOTICE / HINT

CAUTION:
·

Wear protective gloves when removing the exhaust pipe.

·

The exhaust pipe is extremely hot immediately after the engine has stopped.

·

Confirm that the exhaust pipe has cooled down before removing it.



PROCEDURE

Hide 1.REMOVE TAIL EXHUAST PIPE ASSEMBLY

a.

Remove the 2 bolts and 2 compression springs.


b.

Disconnect the 2 exhaust pipe supports and remove the tail exhaust pipe assembly.


c.

Remove the gasket from the center exhaust pipe assembly.

A293428


Hide 2.REMOVE CENTER EXHAUST PIPE ASSEMBLY

a.

Remove the 2 bolts.


b.

Disconnect the 3 exhaust pipe supports and remove the center exhaust pipe assembly.

A293429


c.

Remove the gasket from the front No. 2 exhaust pipe sub-assembly.


Hide 3.REMOVE FRONT NO. 2 EXHAUST PIPE SUB-ASSEMBLY

a.
A293398

Disconnect the heated oxygen sensor connector.


b.
A293431

Remove the 2 bolts and front No. 2 exhaust pipe sub-assembly.


c.

Remove the gasket from the front exhaust pipe sub-assembly.


Hide 4.REMOVE FRONT EXHAUST PIPE SUB-ASSEMBLY

a.
A293430

Remove the 2 bolts, 2 compression springs and front exhaust pipe sub-assembly.


b.

Remove the gasket from the exhaust manifold converter sub-assembly.


Hide 5.REMOVE HEATED OXYGEN SENSOR (for Bank 1 Sensor 2)