Home › Engine / Hybrid System › 2AR-FE COOLING › COOLING FAN MOTOR
RM30B0U _51 Engine / Hybrid System _009233 2AR-FE COOLING _0050392 COOLING FAN MOTOR G

2AR-FE COOLING  COOLING FAN MOTOR  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 1.INSPECT COOLING FAN MOTOR

a.
A297274

Disconnect the cooling fan motor connector.


b.

Check that the fan rotates smoothly by hand.


c.

Check that the motor turns smoothly when the battery is connected to the cooling fan motor connector.


d.

Measure the current according to the value(s) in the table below.

Standard Current:
Tester Connection Condition Specified Condition
2 (+) 20°C (68°F) 7.4 to 10.9 A


If the result is not as specified, replace the cooling fan motor.


e.

Connect the cooling fan motor connector.


Hide 2.INSPECT NO. 2 COOLING FAN MOTOR

a.
A297275

Disconnect the No. 2 cooling fan motor connector.


b.

Check that the fan rotates smoothly by hand.


c.

Check that the motor turns smoothly when the battery is connected to the No. 2 cooling fan motor connector.


d.

Measure the current according to the value(s) in the table below.

Standard Current:
Tester Connection Condition Specified Condition
2 (+) 20°C (68°F) 5.7 to 7.7 A


If the result is not as specified, replace the No. 2 cooling fan motor.


e.

Connect the No. 2 cooling fan motor connector.