Home › Audio / Visual / Telematics › PARK ASSIST / MONITORING › BLIND SPOT MONITOR SYSTEM
RM30B0U _56 Audio / Visual / Telematics _009404 PARK ASSIST / MONITORING _0051188 BLIND SPOT MONITOR SYSTEM J

PARK ASSIST / MONITORING  BLIND SPOT MONITOR SYSTEM  Power Source Circuit  


DESCRIPTION

This circuit provides power to operate the blind spot monitor sensor.

WIRING DIAGRAM

E244551
3.604,0.698 3.917,0.875 0.313,0.177 10 false BLB 3.406,0.583 3.521,0.76 0.115,0.177 10 false 5 3.604,3.281 3.917,3.458 0.313,0.177 10 false BRB 3.406,3.177 3.521,3.354 0.115,0.177 10 false 5 3.604,4.094 4.073,4.292 0.469,0.198 10 false BRGD 3.365,3.979 3.542,4.156 0.177,0.177 10 false 10 3.344,1.375 3.521,1.552 0.177,0.177 10 false 10 3.604,1.49 4.031,1.646 0.427,0.156 10 false BLGD 1.802,0.896 2.365,1.094 0.563,0.198 10 false GAUGE 0.177,0.708 1.156,1.031 0.979,0.323 10 false from IG1 NO. 2 Relay 6.344,0.854 6.875,1.031 0.531,0.177 10 false to CAN 3.146,4.698 3.51,4.854 0.365,0.156 10 false T1 3.083,2.24 5,2.51 1.917,0.271 10 false Blind Spot Monitor Sensor LH 3.156,4.875 5.125,5.156 1.969,0.281 10 false Blind Spot Monitor Sensor RH 0.875,5.281 2.688,5.552 1.813,0.271 10 false : CAN Communication Line 3.094,2.052 3.5,2.208 0.406,0.156 10 false R1

CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses for circuits related to this system before performing the following inspection procedure.


PROCEDURE

1.CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR LH - BATTERY)
E263038
1.5,0.25 1.823,0.521 0.323,0.271 2.021,1.146 2.531,0.51 2.531,0.51 2.729,0.51 false 0.083,0.052 0.396,0.25 0.313,0.198 10 *a 1.573,0.292 1.885,0.49 0.313,0.198 10 R1 2.792,0.427 3.198,0.615 0.406,0.188 10 BLB
*a Front view of wire harness connector
(to Blind Spot Monitor Sensor LH)


a.

Disconnect the blind spot monitor sensor LH connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
R1-5 (BLB) - Body ground Ignition switch ON 11 to 14 V
R1-5 (BLB) - Body ground Ignition switch off Below 1 V



Result:
Proceed to
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR LH - BODY GROUND)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

2.CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR LH - BODY GROUND)
E263038
1.49,0.25 1.833,0.479 0.344,0.229 2,1.354 2.448,1.823 2.448,1.823 2.646,1.823 false 0.083,0.052 0.396,0.25 0.313,0.198 10 *a 1.583,0.292 1.896,0.49 0.313,0.198 10 R1 2.729,1.74 3.135,1.927 0.406,0.188 10 BLGD
*a Front view of wire harness connector
(to Blind Spot Monitor Sensor LH)


a.

Disconnect the blind spot monitor sensor LH connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
R1-10 (BLGD) - Body ground Always Below 1 Ω



Result:
Proceed to
OK
NG



OK

3.CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR RH - BATTERY)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR RH - BATTERY)
a.
E263038
1.5,0.25 1.823,0.49 0.323,0.24 2.01,1.146 2.521,0.51 2.521,0.51 2.719,0.51 false 0.083,0.052 0.396,0.25 0.313,0.198 10 *a 1.583,0.292 1.896,0.49 0.313,0.198 10 T1 2.781,0.427 3.188,0.615 0.406,0.188 10 BRB
*a Front view of wire harness connector
(to Blind Spot Monitor Sensor RH)


Disconnect the blind spot monitor sensor RH connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
T1-5 (BRB) - Body ground Ignition switch ON 11 to 14 V
T1-5 (BRB) - Body ground Ignition switch off Below 1 V



Result:
Proceed to
OK
NG



OK

4.CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR RH - BODY GROUND)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR RH - BODY GROUND)
a.
E263038
1.5,0.25 1.823,0.49 0.323,0.24 2.01,1.292 2.49,1.813 2.49,1.813 2.667,1.813 false 0.083,0.052 0.396,0.25 0.313,0.198 10 false *a 1.583,0.292 1.896,0.49 0.313,0.198 10 false T1 2.76,1.729 3.292,1.927 0.531,0.198 10 false BRGD
*a Front view of wire harness connector
(to Blind Spot Monitor Sensor RH)


Disconnect the blind spot monitor sensor RH connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
T1-10 (BRGD) - Body ground Always Below 1 Ω



Result:
Proceed to
OK
NG



OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR