Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)
RM30B0U _58 Vehicle Interior _009988 HEATING / AIR CONDITIONING _0054778 AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) U

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)  TERMINALS OF ECU  


AIR CONDITIONING AMPLIFIER ASSEMBLY


E226604
3.031,0.115 3.365,0.344 0.333,0.229 5.167,0.115 5.5,0.344 0.333,0.229 5.26,0.135 5.438,0.323 0.177,0.188 10 z7 3.063,0.146 3.375,0.302 0.313,0.156 10 G81

HINT:

Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.


Terminal No.
(Symbol)
Wiring Color Terminal Description Condition Specified Condition

*: w/ Magnet Clutch

G81-1 (IG+) - Body ground GR - Body ground Power source (IG) Ignition switch ON 11 to 14 V
G81-1 (IG+) - Body ground GR - Body ground Power source (IG) Ignition switch off Below 1 V
G81-2 (SOL+) - Body ground BR - Body ground Compressor solenoid operation signal Engine running
Blower switch LO
A/C switch on
Pulse generation
(See waveform 1)
G81-3 (PTC2) - Body ground GR - Body ground Quick heater assembly operation signal Engine running Temperature setting: MAX HOT
Ambient temperature: 10°C or less
Engine coolant temperature: 65°C or less
Light control switch assembly off
Blower switch on
Below 1 V
G81-3 (PTC2) - Body ground GR - Body ground Quick heater assembly operation signal Engine running Temperature setting: MAX HOT
Ambient temperature: 10°C or less
Engine coolant temperature: 65°C or less
Light control switch assembly off
Blower switch off
11 to 14 V
G81-8 (LOCK) - Body ground* W - Body ground A/C lock sensor signal Engine running
Blower switch LO
A/C switch on
Pulse generation
(See waveform 2)
G81-9 (PRE) - G81-13 (SG-2) BE - G Air conditioner pressure sensor signal Engine running
Air conditioning system operating
Refrigerant pressure: Abnormal pressure (higher 3025 kPa [30.8 kgf/cm2, 439 psi])
4.73 V or higher
G81-9 (PRE) - G81-13 (SG-2) BE - G Air conditioner pressure sensor signal Engine running
Air conditioning system operating
Refrigerant pressure: Abnormal pressure (below 176 kPa [1.8 kgf/cm2, 26 psi])
Below 0.62 V
G81-9 (PRE) - G81-13 (SG-2) BE - G Air conditioner pressure sensor signal Engine running
Air conditioning system operating
Refrigerant pressure: Normal pressure (below 3025 kPa [30.8 kgf/cm2, 439 psi] and higher 176 kPa [1.8 kgf/cm2, 26 psi])
0.62 to 4.73 V
G81-10 (S5-3) - G81-13 (SG-2) B - G Power supply for air conditioner pressure sensor Ignition switch ON
A/C switch on
4.75 to 5.25 V
G81-10 (S5-3) - G81-13 (SG-2) B - G Power supply for air conditioner pressure sensor Ignition switch ON
A/C switch off
Below 1 V
G81-11 (CANH) B CAN communication line - -
G81-12 (CANL) W CAN communication line - -
G81-13 (SG-2) - Body ground G - Body ground Ground for air conditioner pressure sensor, ambient temperature sensor, air conditioning lock sensor Always Below 1 V
G81-14 (GND) - Body ground W-B - Body ground Ground for main power supply Always Below 1 Ω
G81-20 (MGC) - Body ground* V - Body ground Magnet clutch operation signal Engine running
Blower switch LO
A/C switch off
11 to 14 V
G81-20 (MGC) - Body ground* V - Body ground Magnet clutch operation signal Engine running
Blower switch LO
A/C switch on
Below 1 V
G81-21 (B) - Body ground GR - Body ground Power source (Back-up) Always 11 to 14 V
G81-22 (BLW) - Body ground R - Body ground Blower motor speed control signal Ignition switch ON
Blower switch LO
Pulse generation
(See waveform 3)
G81-24 (ECOS) - Body ground R - Body ground Combination switch assembly (ECO mode switch) signal Ignition switch ON
Combination switch assembly (ECO mode switch) on
Below 1 V
G81-24 (ECOS) - Body ground R - Body ground Combination switch assembly (ECO mode switch) signal Ignition switch ON
Combination switch assembly (ECO mode switch) off
11 to 14 V
G81-29 (TR) - G81-34 (SG-1) GR - V Room temperature sensor signal Ignition switch ON
Cabin temperature: 25°C (77°F)
1.8 to 2.2 V
G81-29 (TR) - G81-34 (SG-1) GR - V Room temperature sensor signal Ignition switch ON
Cabin temperature: 40°C (104°F)
1.2 to 1.6 V
G81-32 (TSP) - Body ground P - Body ground Solar sensor signal (for Front passenger side) Ignition switch ON
Solar sensor subjected to electric light
0.8 to 4.3 V
G81-32 (TSP) - Body ground P - Body ground Solar sensor signal (for Front passenger side) Ignition switch ON
Solar sensor covered with a cloth
Below 0.8 V
G81-33 (TSD) - Body ground L - Body ground Solar sensor signal (for Driver side) Ignition switch ON
Solar sensor subjected to electric light
0.8 to 4.3 V
G81-33 (TSD) - Body ground L - Body ground Solar sensor signal (for Driver side) Ignition switch ON
Solar sensor covered with a cloth
Below 0.8 V
G81-34 (SG-1) - Body ground V - Body ground Ground for room temperature sensor Always Below 1 V
G81-37 (LIN1) - Body ground B - Body ground LIN communication signal Ignition switch ON Pulse generation
G81-40 (PTC1) - Body ground BR - Body ground Quick heater assembly operation signal Engine running Temperature setting: MAX HOT
Ambient temperature: 10°C or less
Engine coolant temperature: 75°C or less
Light control switch assembly off
Blower switch on
Below 1 V
G81-40 (PTC1) - Body ground BR - Body ground Quick heater assembly operation signal Engine running Temperature setting: MAX HOT
Ambient temperature: 10°C or less
Engine coolant temperature: 75°C or less
Light control switch assembly off
Blower switch off
11 to 14 V
z7-2 (BUS G) - Body ground - Ground for BUS IC Always Below 1 V
z7-3 (BUS) - z7-2 (BUS G) - BUS IC control signal Ignition switch ON Pulse generation
z7-4 (B BUS) - z7-2 (BUS G) - Power supply for BUS IC Always 11 to 14 V
z7-5 (SGA) - Body ground - Ground for evaporator temperature sensor Always Below 1 V
z7-6 (TEA) - z7-5 (SGA) - Evaporator temperature sensor signal Ignition switch ON
Evaporator temperature: 0°C (32°F)
1.7 to 2.1 V
z7-6 (TEA) - z7-5 (SGA) - Evaporator temperature sensor signal Ignition switch ON
Evaporator temperature: 15°C (59°F)
0.9 to 1.3 V

a.
E106664
2.99,1.177 3.396,1.417 0.406,0.24 10 GND

Waveform 1:

Item Content
Terminal No. G81-2 (SOL+) - Body ground
Tool Setting 5 V/DIV., 500 μs/DIV.
Vehicle Condition Engine running
Blower switch LO
A/C switch on


b.
E116941
0.188,0.948 0.552,1.146 0.365,0.198 10 GND

Waveform 2:

Item Content
Terminal No. G81-8 (LOCK) - G81-13 (SG-2)
Tool Setting 200 mV/DIV., 10 ms./DIV.
Vehicle Condition Engine running
Blower switch LO
A/C switch on


c.
E103396
2.917,1.646 3.313,1.854 0.396,0.208 10 GND

Waveform 3:

Item Content
Terminal No. G81-22 (BLW) - Body ground
Tool Setting 1 V/DIV., 500 μs/DIV.
Vehicle Condition Ignition switch ON
Blower switch LO



AIR CONDITIONING CONTROL ASSEMBLY


E270613
1.396,0.302 1.917,0.563 0.521,0.26 1.531,0.354 1.99,0.552 0.458,0.198 10 G20

HINT:

Check from the rear of the connector while it is connected to the air conditioning control assembly.


Terminal No.
(Symbol)
Wiring Color Terminal Description Condition Specified Condition
G20-1 (ILL-) - Body ground BR - Body ground Illumination signal Light control switch off Below 1 V
G20-1 (ILL-) - Body ground BR - Body ground Illumination signal Light control switch tail or head position Pulse generation
G20-4 (ILL+) - Body ground V - Body ground Illumination signal Light control switch off Below 1 V
G20-4 (ILL+) - Body ground V - Body ground Illumination signal Light control switch tail or head position 11 to 14 V
G20-5 (GND) - Body ground BR - Body ground Ground for air conditioning control assembly Always Below 1 Ω
G20-6 (LIN1) - Body ground B - Body ground LIN communication signal Ignition switch ON Pulse generation
G20-8 (IG+) - Body ground BE - Body ground Power source (IG) Ignition switch ON 11 to 14 V
G20-8 (IG+) - Body ground BE - Body ground Power source (IG) Ignition switch off Below 1 V