REFRIGERANT GAS VOLUME CHECK IN NORMAL OPERATION (CHECK A/C SWITCH INDICATOR AND DTC)
Start the engine.
Check that A/C switch indicator remains on when the following conditions are met.
| Item | Condition |
|---|---|
| A/C Switch | On |
| A/C operation time | 15 minutes or more |
| Ambient temperature* | 0 to 49°C (32 to 120°F) |
| Engine coolant temperature | 45°C (113°F) or higher |
*: If the ambient temperature is not within the range shown, do not perform this check.
The A/C switch indicator and air conditioning system turn off if the amount of refrigerant in the system is insufficient.
Connect the Techstream to the DLC3.
Check for DTC B14B8.
REFRIGERANT GAS VOLUME CHECK USING THE TECHSTREAM
Connect the Techstream to the DLC3.
Start the engine.
Turn the Techstream on.
Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.
According to the display on the Techstream, perform the refrigerant gas volume check when the following conditions are met.
| Item | Condition |
|---|---|
|
*: If the ambient temperature is not within the range shown, do not perform this check. |
|
| A/C Switch | On |
| Ambient temperature* | 0 to 49°C (32 to 120°F) |
| R/F Switch | Fresh (Ambient temperature is 31°C [87°F] or higher) |
| Recirculation (Ambient temperature is 30°C [86°F] or less) | |
| Blower Speed | HI |
| Tester Display |
|---|
| Refrigerant Gas Volume Check |
Refer to the Techstream operator's manual for further details.
A message indicating a refrigerant volume gas is displayed on the Techstream and the air conditioning system turns off if the amount of refrigerant in the system is insufficient.
DTCs are not stored when performing the refrigerant gas volume check using the Techstream.
| Result | Amount of Refrigerant | Corrective Action |
|---|---|---|
| Refrigerant shortage | Insufficient or leakage | 2.
Evacuate the air conditioning system and charge it with the appropriate volume of new or purified refrigerant. |
| Refrigerant correct | Correct | - |