1.INSPECT FRONT DOOR WITH MOTOR LOCK ASSEMBLY LH
| *a | Component without harness connected
(Front Door with Motor Lock Assembly LH) |
| *b | Unlock |
| *c | Lock |
Check the operation of the front door lock motor.
Apply battery voltage and check the operation of the front door lock motor.
| Measurement Condition | Specified Condition |
|---|---|
| Battery positive (+) → 4 (L)
Battery negative (-) → 1 (UL) |
Locks |
| Battery positive (+) → 1 (UL)
Battery negative (-) → 4 (L) |
Unlocks |
If the result is not as specified, replace the front door with motor lock assembly LH.
| *a | Component without harness connected
(Front Door with Motor Lock Assembly LH) |
| *b | Unlock |
| *c | Lock |
Check the operation of the door unlock detection switch (w/ Smart Entry and Start System or Theft Deterrent System).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 7 (E) - 8 (LSSR) | Locked | 10 kΩ or higher |
| Unlocked | Below 1 Ω |
If the result is not as specified, replace the front door with motor lock assembly LH.
| *a | Component without harness connected
(Front Door with Motor Lock Assembly LH) |
| *b | Unlock |
| *c | Lock |
Check the operation of the door key lock and unlock switch.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 9 (L) - 7 (E) | Held to lock side | Below 1 Ω |
| 9 (L) - 7 (E) | Neutral or held to unlock side | 10 kΩ or higher |
| 10 (UL) - 7 (E) | Held to unlock side | Below 1 Ω |
| 10 (UL) - 7 (E) | Neutral or held to lock side | 10 kΩ or higher |
If the result is not as specified, replace the front door with motor lock assembly LH.
2.INSPECT FRONT DOOR WITH MOTOR LOCK ASSEMBLY RH
| *a | Component without harness connected
(Front Door with Motor Lock Assembly RH) |
| *b | Unlock |
| *c | Lock |
Check the operation of the front door lock motor.
Apply battery voltage and check the operation of the front door lock motor.
| Measurement Condition | Specified Condition |
|---|---|
| Battery positive (+) → 4 (L)
Battery negative (-) → 1 (UL) |
Locks |
| Battery positive (+) → 1 (UL)
Battery negative (-) → 4 (L) |
Unlocks |
If the result is not as specified, replace the front door with motor lock assembly RH.
| *a | Component without harness connected
(Front Door with Motor Lock Assembly RH) |
| *b | Unlock |
| *c | Lock |
Check the operation of the door unlock detection switch.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 7 (LSSR) - 8 (E) | Locked | 10 kΩ or higher |
| 7 (LSSR) - 8 (E) | Unlocked | Below 1 Ω |
If the result is not as specified, replace the front door with motor lock assembly RH.