Home › Vehicle Interior › HEATING / AIR CONDITIONING › BLOWER RESISTOR
RM30B0U _58 Vehicle Interior _009988 HEATING / AIR CONDITIONING _0054980 BLOWER RESISTOR G

HEATING / AIR CONDITIONING  BLOWER RESISTOR  INSPECTION  


PROCEDURE

Hide 1.INSPECT BLOWER RESISTOR

a.
E145426
1.979,1.167 2.427,0.896 true 1.479,1.177 1.01,0.885 true 1.979,1.552 2.448,1.781 true 1.479,1.552 1.01,1.76 true 0.375,0.229 0.823,0.656 0.448,0.427 10 *a 2.521,0.74 2.938,0.927 0.417,0.188 10 HI 0.76,0.76 1.229,0.958 0.469,0.198 10 M1 2.521,1.781 2.979,1.979 0.458,0.198 10 M2 0.76,1.771 1.219,1.958 0.458,0.188 10 LO
*a Component without harness connected
(Blower Resistor)


Measure the resistance according to the value(s) in the table below.

Standard Resistance for LHD:
Tester Connection Condition Specified Condition
4 (LO) - 1 (HI) Always 3.12 to 3.60 Ω
2 (M1) - 1 (HI) Always 1.45 to 1.67 Ω
3 (M2) - 1 (HI) Always 0.52 to 0.60


Standard Resistance: for RHD:
Tester Connection Condition Specified Condition
1 (LO) - 4 (HI) Always 3.12 to 3.60 Ω
3 (M1) - 4 (HI) Always 1.45 to 1.67 Ω
2 (M2) - 4 (HI) Always 0.52 to 0.60


If the result is not as specified, replace the blower resistor.