Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING PRESSURE SENSOR
RM30B0U _58 Vehicle Interior _009988 HEATING / AIR CONDITIONING _0054990 AIR CONDITIONING PRESSURE SENSOR G

HEATING / AIR CONDITIONING  AIR CONDITIONING PRESSURE SENSOR  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 1.INSPECT AIR CONDITIONER PRESSURE SENSOR (for Automatic Air Conditioning System)

a.

Check the wire harness.

i.

Disconnect the A34 air conditioner pressure sensor connector.


ii.

Disconnect the G81 air conditioning amplifier assembly connector.


iii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A34-1 (-) - G81-13 (SG-2) Always Below 1 Ω
A34-2 (PR) - G81-9 (PRE) Always Below 1 Ω
A34-3 (+) - G81-10 (S5-3) Always Below 1 Ω
A34-1 (-) - Body ground Always 10 kΩ or higher
A34-2 (PR) - Body ground Always 10 kΩ or higher
A34-3 (+) - Body ground Always 10 kΩ or higher


If the resistance is not as specified, repair the wire harness.



iv.

Reconnect the G81 air conditioning amplifier assembly connector.


v.

Turn the ignition switch to ON.


vi.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A34-3 (+) - Body ground Ignition switch ON 4.75 to 5.25 V
A34-3 (+) - Body ground Ignition switch off Below 1 V


If the voltage is not as specified, replace the air conditioning amplifier assembly.




b.

Check the air conditioner pressure sensor.

i.

Install a manifold gauge set.


ii.

Connect the A34 air conditioner pressure sensor connector.


iii.

Start the engine.


iv.

Turn the A/C switch on.


v.
E227427
1.26,0.313 1.646,0.563 0.385,0.25 1.573,1.01 1.969,1.604 true 1.333,1.01 0.938,1.604 true 0.177,0.167 0.333,0.313 0.156,0.146 10 *a 1.854,1.635 2.323,1.969 0.469,0.333 10 PRE 0.719,1.635 1.115,1.781 0.396,0.146 10 SG-2 1.344,0.365 1.646,0.521 0.302,0.156 10 G81
*a Component with harness connected
(Air Conditioning Amplifier Assembly)


Measure the voltage according to the value(s) in the table below.

HINT:

Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.


Standard Voltage:
Tester Connection Condition Specified Condition
G81-9 (PRE) - G81-13 (SG-2) Refrigerant pressure:
(less than 3025 kPa (30.8 kgf/cm2, 439 psi) and more than 176 kPa (1.8 kgf/cm2, 26 psi))
0.74 to 4.62 V


If the voltage is not as specified, replace the air conditioner pressure sensor.




Hide 2.INSPECT AIR CONDITIONER PRESSURE SENSOR (for Manual Air Conditioning System)

a.

Check the wire harness.

i.

Disconnect the A34 air conditioner pressure sensor connector.


ii.

Disconnect the G80 air conditioning amplifier assembly connector.


iii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A34-1 (-) - G80-5 (SG-2) Always Below 1 Ω
A34-2 (PR) - G80-7 (PRE) Always Below 1 Ω
A34-3 (+) - G80-24 (S5-3) Always Below 1 Ω
A34-1 (-) - Body ground Always 10 kΩ or higher
A34-2 (PR) - Body ground Always 10 kΩ or higher
A34-3 (+) - Body ground Always 10 kΩ or higher


If the resistance is not as specified, repair the wire harness.



iv.

Reconnect the G80 air conditioning amplifier assembly connector.


v.

Turn the ignition switch to ON.


vi.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A34-3 (+) - Body ground Ignition switch ON 4.75 to 5.25 V
A34-3 (+) - Body ground Ignition switch off Below 1 V


If the voltage is not as specified, replace the air conditioning amplifier assembly.




b.

Check the air conditioner pressure sensor.

i.

Install a manifold gauge set.


ii.

Connect the A34 air conditioner pressure sensor connector.


iii.

Start the engine.


iv.

Turn the A/C switch on.


v.
E220539
1.5,0.229 1.99,0.51 0.49,0.281 0.875,1.833 1.208,1.156 true 2.406,1.802 1.958,1.156 true 0.198,0.167 0.604,0.5 0.406,0.333 10 *a 0.75,1.844 1.302,2.073 0.552,0.229 10 PRE 2.26,1.823 2.906,2.063 0.646,0.24 10 SG-2 1.625,0.271 2.083,0.469 0.458,0.198 10 G80
*a Component with harness connected
(Air Conditioning Amplifier Assembly)


Measure the voltage according to the value(s) in the table below.

HINT:

Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.


Standard Voltage:
Tester Connection Condition Specified Condition
G80-7 (PRE) - G80-5 (SG-2) Refrigerant pressure:
(less than 3025 kPa (30.8 kgf/cm2, 439 psi) and more than 176 kPa (1.8 kgf/cm2, 26 psi))
0.74 to 4.62 V


If the voltage is not as specified, replace the air conditioner pressure sensor.