U760E AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSAXLE SYSTEM  P2759  Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)  


DESCRIPTION

Refer to DTC P2757.

Click hereDrivetrain>U760E AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSAXLE SYSTEM>P2757

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P2759 Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU) An open or short is detected in the shift solenoid valve SLU circuit for 1 second or more while driving (1-trip detection logic).
·

Open or short in shift solenoid valve SLU circuit

·

Shift solenoid valve SLU

·

Wiring harness connector

·

ECM


Comes on DTC stored

MONITOR DESCRIPTION

When an open or short in the shift solenoid valve SLU circuit is detected, the ECM determines there is a malfunction. The ECM will turn on the MIL and store the DTC.

MONITOR STRATEGY

Related DTCs P2759: Shift solenoid valve SLU/Range check
Required sensors/Components Shift solenoid valve SLU
Frequency of operation Continuous
Duration 1 sec.
MIL operation Immediate
Sequence of operation None

TYPICAL ENABLING CONDITIONS

All
The monitor will run whenever the following DTCs are not stored None
Ignition switch ON
Starter OFF

Condition (A)
Battery voltage 12 V or higher

Condition (B)
Battery voltage 10 V or higher and below 12 V
Target duty cycle Less than 75%

TYPICAL MALFUNCTION THRESHOLDS

Condition (A) and (B)
Output duty cycle 100% or more

COMPONENT OPERATING RANGE

Output duty cycle More than 3% and less than 100%

WIRING DIAGRAM

C239277
5.677,4.354 6.104,4.542 0.427,0.188 10 false ECM 5.083,1.24 5.51,1.427 0.427,0.188 10 false SLU+ 5.083,2.635 5.51,2.823 0.427,0.188 10 false SLU- 3.594,1.229 4.021,1.417 0.427,0.188 10 false SLU+ 3.594,2.635 4.021,2.823 0.427,0.188 10 false SLU- 1.625,1.927 2.563,2.26 0.938,0.333 10 false Shift Solenoid Valve SLU 1.146,3.417 2.5,3.604 1.354,0.188 10 false Transmission Wire 3.083,3.427 4.083,3.781 1,0.354 10 false Wiring Harness Connector 5.677,4.188 5.948,4.344 0.271,0.156 10 false B77 3.104,1.229 3.531,1.417 0.427,0.188 10 false SLU+ 3.104,2.635 3.531,2.823 0.427,0.188 10 false SLU- 2.333,1.229 2.76,1.417 0.427,0.188 10 false SLU+ 2.333,2.635 2.76,2.823 0.427,0.188 10 false SLU- 4.885,1.479 4.99,1.625 0.104,0.146 10 false 7 4.885,2.865 4.99,3.01 0.104,0.146 10 false 6 2.792,1.177 3.01,1.323 0.219,0.146 10 false 11 2.844,2.563 2.969,2.719 0.125,0.156 10 false 5 4.073,1.177 4.281,1.323 0.208,0.146 10 false 14 4.115,2.542 4.229,2.708 0.115,0.167 10 false 5 2.833,2.76 3.104,2.917 0.271,0.156 10 false A 2.823,1.365 3.094,1.521 0.271,0.156 10 false A 4.031,2.75 4.375,2.906 0.344,0.156 10 false B78 4.021,1.365 4.417,1.521 0.396,0.156 10 false B78 1.417,1.708 1.844,1.896 0.427,0.188 10 false 1 1.417,2.365 1.844,2.552 0.427,0.188 10 false 2

CAUTION / NOTICE / HINT

NOTICE:
·

Perform registration and/or initialization when parts related to the automatic transaxle are replaced.

Click hereDrivetrain>U760E AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSAXLE SYSTEM>PRECAUTION

·


PROCEDURE

1.CHECK HARNESS AND CONNECTOR (SHIFT SOLENOID VALVE SLU CIRCUIT)
a.
C267934
1.448,0.177 1.865,0.385 0.417,0.208 0.365,1.719 0.667,0.885 true 1.188,1.708 0.729,0.885 true 1.531,0.208 1.99,0.406 0.458,0.198 10 false B77 0.094,1.75 0.802,1.969 0.708,0.219 10 false 6 (SLU-) 0.99,1.75 1.708,1.969 0.719,0.219 10 false 7 (SLU+) 0.104,0.094 0.417,0.292 0.313,0.198 10 false *a
*a Front view of wire harness connector
(to ECM)


Disconnect the ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
B77-7 (SLU+) - B77-6 (SLU-) 20°C (68°F) 5.0 to 5.6 Ω
B77-7 (SLU+) - Body ground and other terminals Always 10 kΩ or higher
B77-6 (SLU-) - Body ground and other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

NG

2.CHECK HARNESS AND CONNECTOR (WIRING HARNESS CONNECTOR - ECM)
2.CHECK HARNESS AND CONNECTOR (WIRING HARNESS CONNECTOR - ECM)
a.

Disconnect the B78 wiring harness connector.


b.

Disconnect the B77 ECM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
B78-14 (SLU+) - B77-7 (SLU+) Always Below 1 Ω
B78-5 (SLU-) - B77-6 (SLU-) Always Below 1 Ω
B78-14 (SLU+) or B77-7 (SLU+) - Body ground and other terminals Always 10 kΩ or higher
B78-5 (SLU-) or B77-6 (SLU-) - Body ground and other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

3.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLU)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLU)
a.
C226545
0.594,0.76 0.938,1 0.344,0.24 2.323,1.51 2,0.969 true 1.688,1.521 1.99,0.792 true 0.354,0.219 0.667,0.417 0.313,0.198 10 *a 2.177,1.552 2.792,1.75 0.615,0.198 10 SLU+ 0.708,0.792 1.063,0.99 0.354,0.198 10 A 1.531,1.552 2.146,1.75 0.615,0.198 10 SLU-
*a Component without harness connected
(Transmission Wire)


Remove the wiring harness connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A-11 (SLU+) - A-5 (SLU-) 20°C (68°F) 5.0 to 5.6 Ω
A-11 (SLU+) - Body ground and other terminals Always 10 kΩ or higher
A-5 (SLU-) - Body ground and other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

NG

4.INSPECT SHIFT SOLENOID VALVE SLU
4.INSPECT SHIFT SOLENOID VALVE SLU
a.
C197715
1.781,0.969 2.167,0.427 true 1.781,2.948 2.167,2.406 true 1.469,0.969 1.083,0.417 true 1.469,2.948 1.083,2.396 true 0.104,0.104 0.417,0.302 0.313,0.198 10 *1 2.198,0.323 2.375,0.542 0.177,0.219 10 1 2.198,2.302 2.375,2.521 0.177,0.219 10 1 0.969,0.323 1.146,0.542 0.177,0.219 10 2 0.969,2.313 1.146,2.531 0.177,0.219 10 2 1.854,3.938 2.313,4.135 0.458,0.198 10 (+) 1.271,3.938 1.729,4.135 0.458,0.198 10 (-)
*1 Shift Solenoid Valve SLU


Remove shift solenoid valve SLU.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



c.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) with a 21 W bulb → Terminal 1

·

Battery negative (-) → Terminal 2


Valve moves and makes an operating noise



Result:
Proceed to
OK
NG



OK

NG