Refer to DTC P2714.
Click hereDrivetrain>U760E AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSAXLE SYSTEM>P2714
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory |
|---|---|---|---|---|---|
| P2716 | Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT) | An open or short is detected in the shift solenoid valve SLT circuit for 1 sec. or more while driving (1-trip detection logic). | ·
Open or short in shift solenoid valve SLT circuit ·
Shift solenoid valve SLT ·
Wiring harness connector ·
ECM |
Comes on | DTC stored |
When an open or short in the shift solenoid valve SLT circuit is detected, the ECM interprets this as a fault. The ECM will turn on the MIL and store the DTC.
| Related DTCs | P2716: Shift solenoid valve SLT/Range check |
| Required sensors/Components | Shift solenoid valve SLT |
| Frequency of operation | Continuous |
| Duration | 1 sec. |
| MIL operation | Immediate |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not stored | None |
| Solenoid current cut status | Not cut |
| Ignition switch | ON |
| Starter | OFF |
| Battery voltage | 12 V or higher |
| Target current | 1 A |
| Battery voltage | 10 V or higher and below 12 V |
| Target current | Below 0.75 A |
| Battery voltage | 8 V or higher |
| Target current | 1 A |
| Battery voltage | 11 V or higher |
| Target current | 1 A or higher |
| Battery voltage | 11 V or higher |
| Target current | 0.1 A or higher |
| Target voltage - Last Target voltage | Below 0.000019 V |
| Output duty cycle | 100% or more |
| Output duty cycle | 0% or less |
| Solenoid voltage monitor | No signal |
| Target voltage - Average of monitor voltage | 0.035 V or higher |
| Output duty cycle | Less than 100% |
Perform registration and/or initialization when parts related to the automatic transaxle are replaced.
Click hereDrivetrain>U760E AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSAXLE SYSTEM>PRECAUTION
Perform the universal trip to clear permanent DTCs.
Click hereDrivetrain>U760E AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSAXLE SYSTEM>DTC CHECK / CLEAR
| *a | Front view of wire harness connector
(to ECM) |
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B77-15 (SLT+) - B77-14 (SLT-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| B77-15 (SLT+) - Body ground and other terminals | Always | 10 kΩ or higher |
| B77-14 (SLT-) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the B78 wiring harness connector.
Disconnect the B77 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B78-15 (SLT+) - B77-15 (SLT+) | Always | Below 1 Ω |
| B78-7 (SLT-) - B77-14 (SLT-) | Always | Below 1 Ω |
| B78-15 (SLT+) or B77-15 (SLT+) - Body ground and other terminals | Always | 10 kΩ or higher |
| B78-7 (SLT-) or B77-14 (SLT-) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component without harness connected
(Transmission Wire) |
Remove the wiring harness connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A-12 (SLT+) - A-7 (SLT-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| A-12 (SLT+) - Body ground and other terminals | Always | 10 kΩ or higher |
| A-7 (SLT-) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | Shift Solenoid Valve SLT |
Remove shift solenoid valve SLT.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
|---|---|
·
Battery positive (+) with a 21 W bulb → Terminal 1 ·
Battery negative (-) → Terminal 2 |
Valve moves and makes an operating noise |
| Proceed to |
|---|
| OK |
| NG |
OK
NG