The ECM uses signals from the throttle position sensor, air flow meter, turbine (input) speed sensor, intermediate (counter gear) speed sensor and crankshaft position sensor to help determine the engagement timing of the lock-up clutch. The ECM monitors the engagement of the clutch using the turbine (input) speed sensor, intermediate (counter gear) speed sensor and crankshaft position sensor.
Then the ECM compares the engagement condition of the lock-up clutch with the lock-up schedule in the ECM memory to detect mechanical problems of the shift solenoid valve (SL), valve body and torque converter.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory |
|---|---|---|---|---|---|
| P0741 | Torque Converter Clutch Solenoid Performance (Shift Solenoid Valve SL) | Lock-up does not occur when requested (2-trip detection logic). | ·
Shift solenoid valve SL remains closed ·
Transmission valve body assembly is blocked ·
Torque converter assembly ·
Automatic transaxle assembly (clutch, brake or gear etc.) ·
Line pressure is too low |
Comes on | DTC stored |
Torque converter lock-up is controlled by the ECM based on speed sensor NT, speed sensor NC, engine speed, engine load, engine temperature, vehicle speed, ATF temperature and gear selection. The ECM determines the lock-up status of the torque converter by comparing the engine speed (NE) to the input turbine speed (NT). The ECM calculates the actual transmission gear by comparing the input turbine speed (NT) to the counter gear speed (NC). When conditions are appropriate, the ECM requests "lock-up" by applying control voltage to shift solenoid valve SL. When shift solenoid valve SL is turned on, it applies pressure to the lock-up relay valve and locks the torque converter.
If the ECM detects no lock-up after lock-up has been requested or if it detects lock-up when it is not requested, the ECM interprets this as a fault in shift solenoid valve SL or lock-up system performance. The ECM will turn on the MIL and store the DTC.
Example:
When the following is met, the system judges it to be a malfunction.
There is a difference in rotation speed between the input side (engine speed) and output side (input turbine speed) of the torque converter when the ECM commands lock-up.
(Engine speed is at least 70 rpm more than the input turbine speed.)
| Related DTCs | P0741:
Shift solenoid valve SL/OFF malfunction/Functional check |
| Required sensors/Components | Shift solenoid valve SL, Speed sensor (NT), Speed sensor (NC), Crankshaft position sensor (NE), Throttle position sensor (VPA1), Mass air flow sensor (MAF), Transmission temperature sensor (THO1), Engine coolant temperature sensor (ECT) |
| Frequency of operation | Continuous |
| Duration | OFF malfunction: 3.5 sec. |
| MIL operation | 2 driving cycles |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not stored | P0712, P0713 (ATF temperature sensor circuit)
P0115, P0117, P0118 (ECT sensor circuit) P0715, P0717 (Turbine speed sensor circuit) P0791, P0793 (Intermediate shaft speed sensor circuit) P0748 (Shift solenoid valve SL1 circuit) P0778 (Shift solenoid valve SL2 circuit) P0798 (Shift solenoid valve SL3 circuit) P2810 (Shift solenoid valve SL4 circuit) P2759 (Shift solenoid valve SLU circuit) P2769, P2770 (Shift solenoid valve SL circuit) P0327, P0328 (KCS circuit) P0120, P0121, P0122, P0123, P0220, P0222, P0223, P0604, P0606, P060A, P060B, P060D, P060E, P0657, P1607, P2102, P2103, P2111, P2112, P2118, P2119, P2135 (ETCS) U0100 (CAN communication system) |
| ATF temperature sensor circuit | Not circuit malfunction |
| ECT (Engine coolant temperature) sensor circuit | Not circuit malfunction |
| Turbine speed sensor circuit | Not circuit malfunction |
| Intermediate shaft speed sensor circuit | Not circuit malfunction |
| Shift solenoid valve SL1 circuit | Not circuit malfunction |
| Shift solenoid valve SL2 circuit | Not circuit malfunction |
| Shift solenoid valve SL3 circuit | Not circuit malfunction |
| Shift solenoid valve SL4 circuit | Not circuit malfunction |
| Shift solenoid valve SLU circuit | Not circuit malfunction |
| Shift solenoid valve SL circuit | Not circuit malfunction |
| KCS (Knock control sensor) circuit | Not circuit malfunction |
| ETCS (Electronic throttle control system) | Not system down |
| CAN communication system | Not system down |
| Transmission range | "D" |
| Duration time from shifting "N" to "D" | 4 sec. or more |
| ATF temperature | -10°C (14°F) or higher |
| Engine | Starting |
| ECT | 40°C (104°F) or higher |
| Spark advance from Max. retard timing by KCS control | 0°CA or more |
| ECM selected gear | Not 1st |
| Vehicle speed | 25 km/h (15.5 mph) or more |
| Turbine speed / Output speed (NT / NO) in 1st gear | 3.232 to 7.556 |
| Turbine speed / Output speed (NT / NO) in 2nd gear | 1.860 to 2.289 |
| Turbine speed / Output speed (NT / NO) in 3rd gear | 1.369 to 1.613 |
| Turbine speed / Output speed (NT / NO) in 4th gear | 0.976 to 1.113 |
| Turbine speed / Output speed (NT / NO) in 5th gear | 0.690 to 0.818 |
| Turbine speed / Output speed (NT / NO) in 6th gear | 0.556 to 0.680 |
| ECM lock-up command | ON (SL ON, SLU pressure: 513 kPa (5.2 kgf/cm2, 74 psi) or higher) |
| Duration time from lock-up on command | 3 sec. or more |
| Engine Speed - Turbine speed | 70 rpm or more |
Refer to DTC P2769.
Click hereDrivetrain>U760E AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSAXLE SYSTEM>P2769
Perform registration and/or initialization when parts related to the automatic transaxle are replaced.
Click hereDrivetrain>U760E AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSAXLE SYSTEM>PRECAUTION
Perform the universal trip to clear permanent DTCs.
Click hereDrivetrain>U760E AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSAXLE SYSTEM>DTC CHECK / CLEAR
PERFORM ACTIVE TEST
Using the Techstream to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Warm up the engine.
Turn the ignition switch off.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Active Test.
According to the display on the Techstream, perform the Active Test.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Activate the Lock Up | Control shift solenoid valve SLU and SL to set the automatic transaxle to lock-up | ON or OFF | Can be used to check shift solenoid valve SLU and SL operation.
[Vehicle Condition] Vehicle speed: 60 km/h (37 mph) or more |
| Tester Display |
|---|
| Activate the Lock Up |
Lightly depress the accelerator pedal and check that the engine speed does not change abruptly.
When depressing the accelerator pedal while driving, if the engine speed does not change abruptly, lock-up is on.
When decelerating, slowly release the accelerator pedal, but do not fully release it (fully releasing the pedal will close the throttle valve and lock-up may be turned off).
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Read the DTCs using the Techstream.
| Result | Proceed to |
|---|---|
| Only P0741 is output | A |
| P0741 and other DTCs are output | B |
If any other codes besides P0741 are output, perform the troubleshooting for those DTCs first.
A
B
| *a | Component without harness connected
(Transmission Wire) |
Remove the wiring harness connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A-6 (SL) - Body ground | 20°C (68°F) | 11 to 15 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | Shift Solenoid Valve SL |
Remove shift solenoid valve SL.
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
|---|---|
·
Battery positive (+) → Shift solenoid valve SL connector ·
Battery negative (-) → Shift solenoid valve SL body |
Valve moves and makes an operating noise |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check the transmission valve body assembly.
Click hereDrivetrain>U760E AUTOMATIC TRANSMISSION / TRANSAXLE>VALVE BODY ASSEMBLY>DISASSEMBLY
There are no foreign objects on any valve.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check the torque converter assembly.
Click hereDrivetrain>U760E AUTOMATIC TRANSMISSION / TRANSAXLE>TORQUE CONVERTER AND DRIVE PLATE>INSPECTION
The torque converter operates normally.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | Shift Solenoid Valve SL |
Remove shift solenoid valve SL.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Shift solenoid valve SL connector terminal - Shift solenoid valve SL body | 20°C (68°F) | 11 to 15 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG