RM30B0U
_V1
General
_010968
SPECIFICATIONS
_0058351
PARK ASSIST / MONITORING
F
SPECIFICATIONS PARK ASSIST / MONITORING SERVICE DATA
ULTRASONIC SENSOR
| Tester Connection
|
Condition
|
Specified Condition
|
1 (BI) - 5 (EI)
1 (BI) - 2 (BO)
|
Always
|
Below 1 Ω
|
3 (SI) - 4 (SO)
5 (EI) - 6 (EO)
|
Always
|
10 kΩ or higher
|
CLEARANCE SONAR MAIN SWITCH
| Tester Connection
|
Condition
|
Specified Condition
|
| 1 (ECU) - 9 (LAPB)
|
Clearance sonar main switch on
|
Below 1 Ω
|
| Clearance sonar main switch off
|
10 kΩ or higher
|
BLIND SPOT MONITOR MAIN SWITCH
| Tester Connection
|
Condition
|
Specified Condition
|
| 11 (B) - 8 (D)
|
Blind spot monitormain switchassembly on (notprotruding)
|
Below 1 Ω
|
| Blind spot monitormain switchassembly off(protruding)
|
10 kΩ or higher
|