Home › Engine / Hybrid System › 2AR-FE EMISSION CONTROL › EMISSION CONTROL SYSTEM
NM3090E _51 Engine / Hybrid System _008629 2AR-FE EMISSION CONTROL _0048059 EMISSION CONTROL SYSTEM CO CONTROL F

2AR-FE EMISSION CONTROL  EMISSION CONTROL SYSTEM  CONTROL  EVAPORATIVE EMISSION CONTROL  


FUNCTION OF MAIN COMPONETS


a.

The main components of the evaporative emission control system are as follows:

Except Models for Korea
Component Function
ECM Sends signals to the purge VSV to control the purge flow.
Charcoal Canister Contains activated charcoal to absorb the fuel vapor that is created in the fuel tank assembly.
Purge VSV Opens in accordance with the signals from the ECM when the system is purging, in order to send the fuel vapor that was absorbed by the charcoal canister into the intake manifold.

Models for Korea
Component Function
ECM Controls the canister pump module and the purge VSV in accordance with the signals from various sensors, in order to achieve a purge volume that suits the driving conditions. In addition, the ECM monitors the system for any leak and stores a DTC if a malfunction is found.
Charcoal Canister Assembly Contains activated charcoal to absorb the fuel vapor that is created in the fuel tank assembly.
Canister Pump Module Vent Valve Opens and closes the fresh air line in accordance with signals from the ECM.
Leak Detection Pump and Pump Motor Applies vacuum to the evaporative emission system in accordance with signals from the ECM.
Canister Pressure Sensor Detects the pressure in the evaporative emission system and sends the signals to the ECM.
Purge VSV Opens in accordance with the signals from the ECM when the system is purging, in order to send the fuel vapor that was absorbed by the charcoal canister assembly into the intake manifold. In system monitoring mode, this valve controls the introduction of vacuum into the fuel tank assembly.
No. 1 Charcoal Canister Filter Prevents dust and debris in the fresh air from entering the system.
Fresh Air Line Fresh air goes into the charcoal canister assembly and the cleaned drain air goes out into the atmosphere.



OPERATING CONDITION


a.

Models for Korea

i.

The following are the typical conditions necessary to enable an evaporative emission leak check:

Typical Enabling Conditions
·

5 hours have elapsed after the engine has been turned off.*1

·

Altitude: Below 2400 m (8000 feet)

·

Battery Voltage: 10.5 V or more

·

Ignition Switch (Engine Switch*2): Off

·

Engine Coolant Temperature: 4.4 to 35°C (40 to 95°F)

·

Intake Air Temperature: 4.4 to 35°C (40 to 95°F)



*1: If engine coolant temperature does not drop below 35°C (95°F), this time is extended to 7 hours. Even after that, if the temperature is not less than 35°C (95°F), the time is extended to 9.5 hours.

*2: Models with entry and start system


HINT:
·

The canister pump module performs a fuel evaporative emission leak check. This check is performed approximately 5 hours after the engine is turned off. Sound may be heard coming from underneath the luggage compartment for several minutes. This does not indicate a malfunction.

·

A pinpoint pressure test procedure is performed by pressurizing the fresh air line that runs from the canister pump module to the No. 1 charcoal canister filter neck. For details, refer to the Repair Manual.






SYSTEM CONTROL


a.

Except Models for Korea

i.

Based on the signals from various sensors, the ECM opens and closes the purge VSV. Thus, the ECM controls the purge flow of evaporative emissions (HC) in the charcoal canister sub-assembly in accordance with the engine conditions.



b.

Models for Korea

i.

Purge Flow Control

1.

When the engine has reached a predetermined state [closed loop, engine coolant temperature above 80°C (176°F), etc.], stored fuel vapor is purged from the charcoal canister assembly whenever the purge VSV is opened by the ECM.

2.

The ECM changes the duty ratio cycle of the purge VSV, thus controlling purge flow volume. Purge flow volume is determined by the intake manifold pressure and the duty ratio cycle of the purge VSV. Atmospheric pressure is allowed into the charcoal canister assembly to ensure that purge flow is constantly maintained whenever purge vacuum is applied to the charcoal canister assembly.

System Diagram
W100085
6.344,0.865 6.448,0.708 6.448,0.708 6.646,0.708 true 1.625,1.229 1.531,1.063 1.531,1.063 1.396,1.063 true 2.323,1.063 2.271,0.833 true 1.24,1 1.552,1.156 0.313,0.156 10 *1 1.698,2.865 2.01,3.021 0.313,0.156 10 *2 6.677,0.635 6.99,0.792 0.313,0.156 10 *3 1.969,0.385 2.281,0.542 0.313,0.156 10 *a 2.177,0.656 2.49,0.813 0.313,0.156 10 *b
*1 Purge VSV (Open) *2 ECM
*3 Charcoal Canister Assembly - -
*a To Intake Manifold *b Atmosphere




ii.

Onboard Refueling Vapor Recovery (ORVR)

1.

When the internal pressure of the fuel tank assembly increases during refueling, the fuel vapor enters the charcoal canister assembly. The air that has had the fuel vapor removed from it will be discharged through the fresh air line. The vent valve is used to open and close the fresh air line, and it is always open (even when the engine is stopped) except when the vehicle is in monitoring mode (the valve will remain open as long as the vehicle is not in monitoring mode). If the vehicle is refueled in system monitoring mode, the ECM will recognize the refueling by way of the canister pressure sensor, which will detect the sudden pressure increase in the fuel tank assembly, and the ECM will open the vent valve.

System Diagram
W100076
1.031,1.135 0.948,0.958 0.948,0.958 0.74,0.958 true 5.292,2.625 5.427,2.427 5.427,2.427 5.552,2.427 true 6.292,0.75 6.375,0.573 6.375,0.573 6.594,0.573 true 0.531,0.875 0.844,1.073 0.313,0.198 10 false *1 5.563,2.354 5.875,2.552 0.313,0.198 10 false *3 6.635,0.5 6.948,0.698 0.313,0.198 10 false *4 3.823,2.073 4.135,2.271 0.313,0.198 10 false *2
*1 Purge VSV (Closed) *2 Canister Pump Module
*3 Vent Valve *4 Charcoal Canister Assembly




iii.

EVAP Leak Check

1.

General

1.

Approximately 5 hours after the ignition switch (engine switch*) has been turned off, the ECM operates the canister pump module to detect any evaporative emission leakage occurring between the fuel tank assembly and the charcoal canister assembly through changes in the fuel tank assembly pressure.

*: Models with entry and start system


2.

The EVAP leak check operates in accordance with the following timing chart:

Timing Chart
W102532
0.104,0.75 1.229,1.188 1.125,0.438 10 Purge VSV 1.083,0.573 2.208,1.135 1.125,0.563 10 On (Open) 1,0.958 2.146,1.333 1.146,0.375 10 Off (Closed) 1.135,1.771 2.115,2.135 0.979,0.365 10 Off (Vent) 1.552,1.417 1.969,1.833 0.417,0.417 10 On 2.146,4.948 2.552,5.26 0.406,0.313 10 1) 2.865,4.958 3.333,5.292 0.469,0.333 10 2) 4.302,4.958 4.74,5.292 0.438,0.333 10 3) 5.49,4.958 5.854,5.271 0.365,0.313 10 4) 6.208,4.969 6.594,5.26 0.385,0.292 10 5) 6.917,4.958 7.146,5.271 0.229,0.313 10 6) 1.542,2.573 1.99,2.948 0.448,0.375 10 Off 1.552,2.208 1.979,2.594 0.427,0.385 10 On 0.104,1.552 1.177,1.885 1.073,0.333 10 Vent Valve 0.104,2.365 1.24,2.708 1.135,0.344 10 Pump Motor 0.406,3.344 1.979,3.76 1.573,0.417 10 Atmospheric Pressure 0.094,3.885 1.604,4.375 1.51,0.49 10 System Pressure 0.729,4.469 2.26,4.896 1.531,0.427 10 0.02 in. Pressure

Order Operation Description Time
1) Atmospheric Pressure Measurement The ECM turns the vent valve off (vent) and measures EVAP system pressure to determine the atmospheric pressure. 60 sec.
2) 0.02 in. Leak Pressure Measurement The leak detection pump creates negative pressure (vacuum) limited by a 0.02 in. orifice, and the pressure is measured. The ECM determines this as the 0.02 in. leak pressure (reference pressure). 360 sec.
3) EVAP Leak Check The leak detection pump creates negative pressure (vacuum) in the EVAP system and the EVAP system pressure is measured. If the stabilized pressure is larger than the 0.02 in. leak pressure, the ECM determines that the EVAP system has a leak. If the EVAP pressure does not stabilize within 15 minutes, the ECM cancels the EVAP monitor. Within 15 min.
4) Purge VSV Monitor The ECM opens the purge VSV and measures the EVAP pressure increase. If the increase is large, the ECM interprets this as normal. 10 sec.
5) Repeat 0.02 in. Leak Pressure Measurement The leak detection pump creates negative pressure (vacuum) limited by a 0.02 in. orifice and the pressure is measured. The ECM determines this as the 0.02 in. leak pressure. 60 sec.
6) Final Check The ECM measures the atmospheric pressure and records the monitor result. -


2.

Atmospheric Pressure Measurement

1.

When the ignition switch (engine switch*) is turned off, the purge VSV and the vent valve are turned off. Therefore, atmospheric pressure is introduced into the charcoal canister assembly.

*: Models with entry and start system


2.

The ECM measures the atmospheric pressure using the canister pressure sensor.

3.

If the measured atmospheric pressure is out of range, the ECM actuates the leak detection pump in order to monitor the changes in the pressure.

System Diagram
W111609
1.26,0.906 1.156,0.729 1.156,0.729 0.969,0.729 true 5.313,2.344 5.438,2.167 5.438,2.167 5.521,2.167 true 0.813,0.656 1.125,0.854 0.313,0.198 10 *1 1.333,2.583 1.646,2.781 0.313,0.198 10 *2 3.917,1.802 4.229,2 0.313,0.198 10 *3 5.542,2.094 5.854,2.292 0.313,0.198 10 *4 1.865,0.573 2.177,0.771 0.313,0.198 10 *a
*1 Purge VSV (Off) *2 ECM
*3 Canister Pump Module *4 Vent Valve (Off)
*a Atmosphere - -


Timing Chart
W111610
3.563,4.563 3.406,4.563 3.406,4.563 3.271,4.25 true 0.198,0.552 0.99,0.885 0.792,0.333 10 Purge VSV 2.271,0.375 2.979,0.688 0.708,0.313 10 On (Open) 2.188,0.75 2.979,1.125 0.792,0.375 10 Off (Closed) 0.198,1.302 0.99,1.708 0.792,0.406 10 Vent Valve 2.677,1.146 3,1.49 0.323,0.344 10 On 2.313,1.521 2.99,1.875 0.677,0.354 10 Off (Vent) 0.188,2.104 1.104,2.458 0.917,0.354 10 Pump Motor 2.667,1.917 2.948,2.25 0.281,0.333 10 On 2.656,2.313 2.969,2.615 0.313,0.302 10 Off 1.479,2.719 2.948,3.177 1.469,0.458 10 Atmospheric Pressure 1.792,3.604 2.969,4.031 1.177,0.427 10 0.02 in. Pressure 0.188,3.167 1.406,3.521 1.219,0.354 10 System Pressure 3.594,4.479 5.875,4.781 2.281,0.302 10 Atmospheric Pressure Measurement


3.

0.02 in. Leak Pressure Measurement

1.

The purpose of this measurement is to confirm leak detection pump operation, and to provide a baseline measurement value that is used for comparison in subsequent leak test steps.

2.

The vent valve remains off, atmospheric pressure is introduced into the charcoal canister assembly and the ECM actuates the leak detection pump, creating a vacuum in the piping close to the canister pressure sensor.

3.

At this time, the pressure will not decrease below what is referred to as the 0.02 in. pressure due to the atmospheric pressure that enters the piping close to the pump and sensor through the 0.02 in. diameter reference orifice.

4.

The ECM compares its standard and this pressure. If the pressure is within the acceptable range, the ECM stores this pressure as the 0.02 in. leak pressure.

5.

If the pressure is below the standard, the ECM will determine that the reference orifice is clogged and store DTC P043E in its memory.

6.

If the pressure is above the standard, the ECM will determine that a high flow rate pressure is passing through the reference orifice and store DTCs P043F, P2401 and P2402 in its memory.

System Diagram
W111611
1.26,0.885 1.125,0.688 1.125,0.688 0.969,0.688 true 5.302,2.323 5.417,2.146 5.417,2.146 5.531,2.146 true 5.25,3.063 5.313,3.156 5.313,3.156 5.469,3.156 true 0.792,0.583 1.104,0.74 0.313,0.156 10 *1 1.344,2.573 1.656,2.729 0.313,0.156 10 *2 3.938,1.792 4.25,1.948 0.313,0.156 10 *3 5.563,2.083 5.875,2.24 0.313,0.156 10 *4 1.875,0.563 2.188,0.719 0.313,0.156 10 *a 5.51,3.063 5.823,3.219 0.313,0.156 10 *5
*1 Purge VSV (Off) *2 ECM
*3 Canister Pump Module *4 Vent Valve (Off)
*5 Reference Orifice - -
*a Atmosphere - -


Timing Chart
W111612
4.115,4.51 3.833,4.51 3.833,4.51 3.667,4.24 true 0.167,0.521 1.177,0.917 1.01,0.396 10 Purge VSV 2.073,0.385 2.771,0.698 0.698,0.313 10 On (Open) 1.99,0.771 2.771,1.104 0.781,0.333 10 Off (Closed) 0.167,1.281 1.198,1.667 1.031,0.385 10 Vent Valve 2.458,1.135 2.781,1.438 0.323,0.302 10 On 2.125,1.542 2.781,1.844 0.656,0.302 10 Off (Vent) 0.146,2.073 1.156,2.469 1.01,0.396 10 Pump Motor 2.448,1.917 2.781,2.229 0.333,0.313 10 On 2.427,2.313 2.76,2.604 0.333,0.292 10 Off 1.281,2.74 2.74,3.104 1.458,0.365 10 Atmospheric Pressure 0.156,3.125 1.531,3.323 1.375,0.198 10 System Pressure 1.594,3.594 2.74,3.969 1.146,0.375 10 0.02 in. Pressure 4.208,4.448 6.198,4.813 1.99,0.365 10 0.02 in. Pressure Measurement


4.

EVAP Leak Check

1.

While actuating the leak detection pump, the ECM turns the vent valve on in order to introduce a vacuum into the charcoal canister assembly.

2.

When the pressure in the system stabilizes, the ECM compares this pressure and the 0.02 in. pressure in order to determine if a leak is present.

3.

If the detected pressure is below the 0.02 in. pressure, the ECM determines that there is no leak.

4.

If the detected pressure is above the 0.02 in. pressure and near atmospheric pressure, the ECM determines that there is a gross leak (large hole) and stores DTC P0455 in its memory.

5.

If the detected pressure is above the 0.02 in. pressure, the ECM determines that there is a small leak (minor leak) and stores DTC P0456 in its memory.

System Diagram
W111613
1.25,0.906 1.115,0.729 1.115,0.729 0.917,0.729 true 6.208,1.146 6.563,0.885 6.563,0.885 6.771,0.885 true 5.25,3.052 5.323,3.125 5.323,3.125 5.438,3.125 true 5.333,2.219 5.427,2.094 5.427,2.094 5.552,2.094 true 0.708,0.667 1.021,0.823 0.313,0.156 10 *1 1.344,2.656 1.656,2.813 0.313,0.156 10 *2 3.938,1.802 4.25,1.958 0.313,0.156 10 *3 5.583,2.01 5.896,2.167 0.313,0.156 10 *4 5.469,3.073 5.781,3.229 0.313,0.156 10 *5 1.854,0.49 2.167,0.646 0.313,0.156 10 *a 6.792,0.823 7.104,0.979 0.313,0.156 10 *b
*1 Purge VSV (Off) *2 ECM
*3 Canister Pump Module *4 Vent Valve (On)
*5 Reference Orifice - -
*a Atmosphere *b Vacuum


Timing Chart
W111614
4.094,2.823 3.927,2.49 3.927,2.49 3.573,2.49 true 4.094,3.323 3.927,2.99 3.927,2.99 3.573,2.99 true 4.833,3.781 5.396,2.51 5.396,2.51 5.646,2.51 true 4.906,4.542 4.635,4.542 4.635,4.542 4.49,4.229 true 0.094,0.49 1.135,0.917 1.042,0.427 10 Purge VSV 1.792,0.365 2.552,0.719 0.76,0.354 10 On (Open) 1.708,0.76 2.552,1.104 0.844,0.344 10 Off (Closed) 0.125,1.281 1.208,1.688 1.083,0.406 10 Vent Valve 2.198,1.146 2.552,1.458 0.354,0.313 10 On 1.844,1.5 2.542,1.844 0.698,0.344 10 Off (Vent) 0.125,2.052 1.229,2.458 1.104,0.406 10 Pump Motor 2.198,1.906 2.563,2.219 0.365,0.313 10 On 2.198,2.281 2.573,2.594 0.375,0.313 10 Off 1.031,2.708 2.49,3.073 1.458,0.365 10 Atmospheric Pressure 0.135,3.146 1.344,3.51 1.208,0.365 10 System Pressure 1.344,3.583 2.531,3.948 1.188,0.365 10 0.02 in. Pressure 4.948,4.458 6.271,4.813 1.323,0.354 10 EVAP Leak Check 3.115,2.417 3.625,2.802 0.51,0.385 10 P0455 3.115,2.896 3.625,3.281 0.51,0.385 10 P0456 5.698,2.417 6.208,2.802 0.51,0.385 10 Normal


5.

Purge VSV Monitor

1.

After completing an EVAP leak check, the ECM turns the purge VSV on (open) with the leak detection pump actuated, and introduces the atmospheric pressure from the intake manifold to the charcoal canister assembly.

2.

If the pressure change at this time is within the normal range (a pressure change occurs), the ECM determines the condition to be normal.

3.

If the pressure change is out of the normal range (insufficient pressure change occurs), the ECM will stop the purge VSV monitor (purge monitor) and store DTC P0441 in its memory.

System Diagram
W111615
1.25,0.896 1.115,0.698 1.115,0.698 0.927,0.698 true 5.323,2.25 5.427,2.115 5.427,2.115 5.542,2.115 true 0.76,0.604 1.073,0.76 0.313,0.156 10 *1 1.344,2.635 1.656,2.792 0.313,0.156 10 *2 3.917,1.792 4.229,1.948 0.313,0.156 10 *3 5.583,2.031 5.896,2.188 0.313,0.156 10 *4 1.625,0.01 1.938,0.167 0.313,0.156 10 *a 1.875,0.49 2.188,0.646 0.313,0.156 10 *a
*1 Purge VSV (On) *2 ECM
*3 Canister Pump Module *4 Vent Valve (On)
*a Atmosphere - -


Timing Chart
W111616
5.396,4.542 5.24,4.542 5.24,4.542 5.052,4.25 true 4.958,3.229 4.781,3.01 4.781,3.01 4.583,3.01 true 5.083,3.771 5.385,3.25 5.385,3.25 5.51,3.25 true 0.073,0.542 1.229,0.865 1.156,0.323 10 Purge VSV 1.49,0.365 2.281,0.688 0.792,0.323 10 On (Open) 1.406,0.74 2.26,1.094 0.854,0.354 10 Off (Closed) 0.073,1.281 0.917,1.698 0.844,0.417 10 Vent Valve 1.885,1.115 2.24,1.417 0.354,0.302 10 On 1.552,1.51 2.229,1.802 0.677,0.292 10 Off (Vent) 0.073,2.073 1.063,2.417 0.99,0.344 10 Pump Motor 1.885,1.885 2.229,2.167 0.344,0.281 10 On 1.885,2.281 2.219,2.573 0.333,0.292 10 Off 0.75,2.708 2.177,3.052 1.427,0.344 10 Atmospheric Pressure 0.073,3.156 1.302,3.552 1.229,0.396 10 System Pressure 1.063,3.594 2.208,3.938 1.146,0.344 10 0.02 in. Pressure 5.458,4.458 6.833,4.781 1.375,0.323 10 Purge VSV Monitor 4.073,2.938 4.698,3.313 0.625,0.375 10 Normal 5.563,3.177 6.188,3.552 0.625,0.375 10 P0441


6.

Repeat 0.02 in. Leak Pressure Measurement

1.

While the ECM operates the leak detection pump, the purge VSV and vent valve are turned off and a repeat 0.02 in. leak pressure measurement is performed.

2.

The ECM compares the measured pressure with the pressure during the EVAP leak check.

3.

If the pressure during the EVAP leak check is less than the repeat 0.02 in. leak pressure measurement, the ECM determines that there is no leak.

4.

If the pressure during the EVAP leak check is above the repeat 0.02 in. leak pressure measurement, the ECM determines that there is a small leak and stores DTC P0456 in its memory.

System Diagram
W111617
1.271,0.896 1.115,0.667 1.115,0.667 0.927,0.667 true 5.313,2.333 5.458,2.073 5.458,2.073 5.552,2.073 true 5.25,3.052 5.323,3.146 5.323,3.146 5.427,3.146 true 0.74,0.583 1.052,0.74 0.313,0.156 10 *1 1.344,2.615 1.656,2.771 0.313,0.156 10 *2 3.927,1.792 4.24,1.948 0.313,0.156 10 *3 5.583,2 5.896,2.156 0.313,0.156 10 *4 1.896,0.542 2.208,0.698 0.313,0.156 10 *a 5.458,3.073 5.771,3.229 0.313,0.156 10 *5
*1 Purge VSV (Off) *2 ECM
*3 Canister Pump Module *4 Vent Valve (Off)
*5 Reference Orifice - -
*a Atmosphere - -


Timing Chart
W111618
5.458,4.542 5.667,4.542 5.667,4.542 5.958,4.24 true 4.104,3.417 4.229,2.938 4.229,2.938 4.396,2.938 true 4.406,3.646 4.5,3.313 4.5,3.313 4.646,3.313 true 0.115,0.573 0.958,0.948 0.844,0.375 10 Purge VSV 1.802,0.385 2.531,0.708 0.729,0.323 10 On (Open) 1.729,0.76 2.51,1.115 0.781,0.354 10 Off (Closed) 0.094,1.302 0.896,1.656 0.802,0.354 10 Vent Valve 2.198,1.135 2.458,1.417 0.26,0.281 10 On 1.865,1.531 2.531,1.833 0.667,0.302 10 Off (Vent) 0.083,2.125 1.031,2.51 0.948,0.385 10 Pump Motor 2.198,1.927 2.51,2.208 0.313,0.281 10 On 2.198,2.323 2.531,2.625 0.333,0.302 10 Off 1.042,2.729 2.479,3.104 1.438,0.375 10 Atmospheric Pressure 0.073,3.156 1.333,3.521 1.26,0.365 10 System Pressure 1.344,3.604 2.51,3.927 1.167,0.323 10 0.02 in. Pressure 2.969,4.448 5.406,4.76 2.438,0.313 10 Repeat 0.02 in. Pressure Measurement 4.458,2.885 4.938,3.198 0.479,0.313 10 P0456 4.688,3.24 5.167,3.552 0.479,0.313 10 Normal