Home › Engine / Hybrid System › 3ZR-FAE ENGINE CONTROL › SFI SYSTEM
NM3090E _51 Engine / Hybrid System _008644 3ZR-FAE ENGINE CONTROL _0048051 SFI SYSTEM DE DETAILS F

3ZR-FAE ENGINE CONTROL  SFI SYSTEM  DETAILS  AIR FUEL RATIO SENSOR AND HEATED OXYGEN SENSOR  


CONSTRUCTION


a.

The basic construction of the air fuel ratio sensor and oxygen sensor is the same. However, they are divided into the cup type and the planar type, in accordance with the different types of heater construction that are used.


b.

The planar type air fuel ratio sensor uses alumina, which excels in heat conductivity and insulation, to integrate a sensor element with the heater, thus achieving the excellent warm-up performance of the sensor.


c.

The cup type oxygen sensor contains a sensor element that surrounds the heater.

W100282
0.208,0.208 3.438,4.625 3.229,4.417 3.708,0.208 6.938,4.625 3.229,4.417 2.531,2.5 2.135,2.208 true 2.583,2.385 2.292,1.948 true 2.771,2.365 2.635,1.854 true 3.073,2.271 2.74,2.708 true 2.719,2.938 1.813,3.625 1.813,3.625 2.594,2.854 true 2.563,3.667 2.656,3.281 true 3.063,3.563 2.844,3.26 true 6.188,2.292 6.427,1.792 true 6,2.365 5.854,1.552 true 5.854,2.281 5.531,1.854 5.531,1.854 5.74,2.281 true 0.26,0.25 0.583,0.469 0.323,0.219 12 *A: 3.76,0.25 4.083,0.49 0.323,0.24 12 *B: 1.979,2.083 2.292,2.24 0.313,0.156 10 *1 2.146,1.802 2.458,1.958 0.313,0.156 10 *2 1.667,3.604 1.979,3.76 0.313,0.156 10 *3 2.448,3.698 2.76,3.854 0.313,0.156 10 *4 5.781,1.375 6.094,1.531 0.313,0.156 10 *5 3.104,2.167 3.417,2.323 0.313,0.156 10 *6 2.531,1.646 2.844,1.802 0.313,0.156 10 *1 3.031,3.583 3.344,3.74 0.313,0.156 10 *5 6.417,1.615 6.729,1.771 0.313,0.156 10 *6 5.385,1.677 5.698,1.833 0.313,0.156 10 *3
*A Planar Type Air Fuel Ratio Sensor *B Cup Type Oxygen Sensor
*1 Alumina *2 Dilation Layer
*3 Platinum Electrode *4 Sensor Element (Zirconia)
*5 Heater *6 Atmosphere



d.

As illustrated below, the conventional oxygen sensor is characterized by a sudden change in its output voltage at the threshold of the stoichiometric air fuel ratio (14.7:1). In contrast, the air fuel ratio sensor data is approximately proportionate to the existing air fuel ratio. The air fuel ratio sensor converts the oxygen density to current and sends it to the ECM. As a result, the detection precision of the air fuel ratio has been improved. The air fuel ratio sensor data can be viewed using a Global TechStream (GTS).

W100042
2.427,0.167 2.729,0.167 2.729,0.167 3.167,1.24 true 4.667,0.25 4.281,0.25 4.281,0.25 3.99,1.604 true 2.146,3.604 2.76,3.927 0.615,0.323 10 11 (Rich) 5.073,3.625 5.76,3.979 0.688,0.354 10 19 (Lean) 3.323,3.625 3.625,3.885 0.302,0.26 10 14.7 3.292,3.865 4.24,4.198 0.948,0.333 10 Air Fuel Ratio 5.208,0.469 5.438,0.667 0.229,0.198 10 (V) 1.896,0.448 2.125,0.646 0.229,0.198 10 (V) 5.406,0.76 5.552,0.958 0.146,0.198 10 1 5.448,3.188 5.688,3.385 0.24,0.198 10 0.1 1.667,3.219 1.938,3.51 0.271,0.292 10 2.2 1.677,0.802 1.948,0.979 0.271,0.177 10 4.2 5.417,1.469 6.49,2.146 1.073,0.677 10 Oxygen Sensor Output 0.458,1.469 2.021,2.76 1.563,1.292 10 Air Fuel Ratio Sensor Output* (Data Displayed on Global TechStream (GTS)) 4.719,0.177 6.115,0.438 1.396,0.26 10 Air Fuel Ratio Sensor 0.375,4.271 5.844,4.604 5.469,0.333 10 *: This value is calculated internally in the ECM and is not an ECM terminal voltage. 1.406,0.104 2.906,0.396 1.5,0.292 10 Oxygen Sensor