Home › Drivetrain › K111F MULTIDRIVE / CVT › CVT SYSTEM
NM3090E _52 Drivetrain _008831 K111F MULTIDRIVE / CVT _0054894 CVT SYSTEM DE DETAILS F

K111F MULTIDRIVE / CVT  CVT SYSTEM  DETAILS  SHIFT SOLENOID VALVE  


CONSTRUCTION


a.

Shift solenoid valves DS1, DS2, DSU and SL use a 3-way solenoid valve.

i.

Shift solenoid valve DS1 controls acceleration by increasing the fluid flow volume to the primary pulley.


ii.

Shift solenoid valve DS2 controls deceleration by increasing the fluid flow volume from the primary pulley.


iii.

Shift solenoid valve DSU is used for the lock-up clutch pressure control.


iv.

Shift solenoid valve SL switches the control of shift solenoid valve SLS.

X112060
2.219,1.469 2.531,1.625 0.313,0.156 10 *a 5.26,1.458 5.573,1.615 0.313,0.156 10 *b
*a Off Condition *b On Condition
V100135

Drain
V100136

Control Pressure
V100137

Line Pressure - -




b.

Shift solenoid valve SLS uses a linear solenoid valve.

i.

Shift solenoid valve SLS controls the hydraulic pressure applied to the secondary pulley in order to control the belt clamping pressure necessary for transmitting torque.


ii.

The action of shift solenoid valve SL controls the line pressure during forward clutch engagement.

X112061
2.094,0.594 1.927,0.229 1.927,0.229 1.677,0.229 true 1.771,0.76 1.573,1.052 1.573,1.052 1.365,1.052 true 2.99,1 3.083,1.26 3.083,1.26 3.333,1.26 true 1.219,0.146 1.76,0.469 0.542,0.323 10 false Sleeve 0.604,0.969 1.427,1.219 0.823,0.25 10 false Spool Valve 3.385,1.188 4.281,1.438 0.896,0.25 10 false Solenoid Coil 1.656,1.469 3.25,1.75 1.594,0.281 10 false Shift Solenoid Valve SLS 4.188,0.208 4.813,0.698 0.625,0.49 10 false Hydraulic Pressure 5.75,1.49 6.323,1.75 0.573,0.26 10 false Current

Function of Shift Solenoid Valve
Shift Solenoid Valve Function
Shift Solenoid Valve DS1 Controls the fluid inflow volume to the primary pulley.
Shift Solenoid Valve DS2 Controls the fluid outflow volume to the primary pulley.
Shift Solenoid Valve DSU Controls the lock-up clutch pressure.
Shift Solenoid Valve SL Switches the control of the shift solenoid valve SLS.
Shift Solenoid Valve SLS
·

Controls the belt clamping pressure.

·