Home › Engine / Hybrid System › 3ZR-FAE STARTING › STARTING SYSTEM › 2015.04–2015.10
NM3090E _51 Engine / Hybrid System _008651 3ZR-FAE STARTING _0048075 STARTING SYSTEM GE GENERAL F

3ZR-FAE STARTING  STARTING SYSTEM  GENERAL  GENERAL  


OUTLINE


a.

Models with Idling Stop Control

i.

A tandem solenoid type starter assembly is used. This starter uses a structure in which the flow of current is independently supplied to the motor current solenoid and the solenoid used to push out the pinion gear. Due to this, it is possible to restart the engine when the engine has been stopped but is still moving due to inertia, thereby reducing the amount of time to restart the engine during idling stop control.

W127052C01
2.396,1.615 2.885,2.542 true 4.656,0.875 4.917,1.385 true 5.854,0.823 5.656,1.469 true 2.906,2.625 3.219,2.781 0.313,0.156 10 false *1 4.51,0.646 4.823,0.802 0.313,0.156 10 false *2 5.823,0.625 6.135,0.781 0.313,0.156 10 false *3 5.24,2.802 5.552,2.958 0.313,0.156 10 false *a
*1 Tandem Solenoid *2 Solenoid to Push Out Pinion Gear
*3 Motor Current Solenoid - -
*a Tandem Solenoid Cross Section - -




b.

Models without Idling Stop Control

i.

A conventional planetary reduction type starter is used.




SPECIFICATION


Models with Idling Stop Control
Starter Type Tandem Solenoid
Rating Output 1.7 kW
Rating Voltage 12 V
Length*1 162.6 mm (5.83 in.)
Weight 4000 g (8.8 lb)
Rotational Direction*2 Clockwise

*1: Length from the mounted area to the rear end of the starter

*2: Viewed from pinion side


Models without Idling Stop Control
Rating Output 1.0 kW
Rating Voltage 12 V
Length*1 163.6 mm (6.4 in.)
Weight 3100 g (6.8 lb)
Rotational Direction*2 Clockwise

*1: Length from the mounted area to the rear end of the starter

*2: Viewed from pinion side