Home › Engine / Hybrid System › 3ZR-FAE STARTING › STARTING SYSTEM › 2015.10–2016.08
NM3090E _51 Engine / Hybrid System _008651 3ZR-FAE STARTING _0048075 STARTING SYSTEM GE GENERAL F

3ZR-FAE STARTING  STARTING SYSTEM  GENERAL  GENERAL  


OUTLINE


a.

Models with Idling Stop Control

i.

A tandem solenoid type starter assembly is used. This starter uses a structure in which the flow of current is independently supplied to the motor current solenoid and the solenoid used to push out the pinion gear. Due to this, it is possible to restart the engine when the engine has been stopped but is still moving due to inertia, thereby reducing the amount of time to restart the engine during idling stop control.*1


ii.

A planetary reduction type starter is used.*2

*1: Models with automatic transaxle

*2: Models with manual transaxle




b.

Models without Idling Stop Control

i.

A conventional planetary reduction type starter is used.




SPECIFICATION


Models with Idling Stop Control
Model Models with Continuously Variable Transaxle (CVT) Models with Manual Transaxle
Starter Type Tandem Solenoid Planetary Reduction
Rating Output 1.7 kW
Rating Voltage 12 V
Length*1 162.6 mm (5.83 in.)
Weight 4000 g (8.8 lb) 3300 g (7.3 lb)
Rotational Direction*2 Clockwise

*1: Length from the mounted area to the rear end of the starter

*2: Viewed from pinion side


Models without Idling Stop Control
Models Except Models for Russia Models for Russia
Rating Output 1.0 kW 1.3 kw
Rating Voltage 12 V 12 V
Length*1 163.6 mm (6.44 in.) 133.1 mm (5.24 in)
Weight 3100 g (6.8 lb) 2750 g (6.1 lb)
Rotational Direction*2 Clockwise Clockwise

*1: Length from the mounted area to the rear end of the starter

*2: Viewed from pinion side