Home › Engine / Hybrid System › 2AD-FTV COOLING › THERMOSTAT
RM3090E _51 Engine / Hybrid System _008373 2AD-FTV COOLING _0046725 THERMOSTAT G

2AD-FTV COOLING  THERMOSTAT  INSPECTION  


PROCEDURE

Hide 16331A 1.INSPECT THERMOSTAT

A299152

HINT:

The valve opening temperature is inscribed on the thermostat.


a.

Immerse the thermostat in water, and then gradually heat the water.


b.

Check the valve opening temperature of the thermostat.

Standard valve opening temperature:

80 to 84°C (176 to 183°F)


If the valve opening temperature is not as specified, replace the thermostat.


c.
A299153
2.458,1.625 2.771,1.781 0.313,0.156 10 false *1
*1 Valve Lift


Check the valve lift.

Standard valve lift:

10 to 14 mm (0.394 to 0.551 in.) at 95°C (203°F)


If the valve lift is not as specified, replace the thermostat.


d.

Check that the valve is fully closed when the thermostat is at a low temperature (below 77°C (171°F)).

If not fully closed, replace the thermostat.