Home › Engine / Hybrid System › 3ZR-FAE FUEL › FUEL PUMP
RM3090E _51 Engine / Hybrid System _008388 3ZR-FAE FUEL _0046821 FUEL PUMP G

3ZR-FAE FUEL  FUEL PUMP  INSPECTION  


PROCEDURE

Hide 23221 1.INSPECT FUEL PUMP

a.

Check the resistance.

i.
A298970
1.083,1.667 1.25,1.667 1.25,1.667 1.573,1.219 true 2.417,1.667 2.25,1.667 2.25,1.667 1.896,1.229 true 0.104,0.094 0.417,0.25 0.313,0.156 10 *a 0.958,1.573 1.115,1.771 0.156,0.198 10 1 2.469,1.573 2.625,1.771 0.156,0.198 10 2
*a Component without harness connected
(Fuel Pump)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 0.2 to 3.0 Ω


If the result is not as specified, replace the fuel pump.



b.

Check the fuel pump operation.

i.

Connect the positive (+) lead of the battery to terminal 1 of the connector, and the negative (-) lead to terminal 2. Check that the fuel pump operates.

If the fuel pump does not operate, replace the fuel pump.

NOTICE:
·

These tests must be performed within 10 seconds to prevent the coil from burning out.

·

Keep the fuel pump as far away from the battery as possible.

·

Always turn the voltage on and off on the battery side, not the fuel pump side.