Home › Engine / Hybrid System › 2AR-FE ENGINE CONTROL › HEATED OXYGEN SENSOR
RM3090E _51 Engine / Hybrid System _008378 2AR-FE ENGINE CONTROL _0046931 HEATED OXYGEN SENSOR G

2AR-FE ENGINE CONTROL  HEATED OXYGEN SENSOR  INSPECTION  


PROCEDURE

Hide 89465 1.INSPECT HEATED OXYGEN SENSOR (for Bank 1 Sensor 2)

a.
A196092
0.917,1.125 1.063,1.125 1.063,1.125 1.396,1.313 false 2.552,1.125 2.417,1.125 2.417,1.125 2.073,1.313 false 2.615,1.031 3,1.188 0.385,0.156 10 HT1B 0.646,1.042 0.854,1.198 0.208,0.156 10 +B 0.042,0.052 0.219,0.24 0.177,0.188 10 *a
*a Component without harness connected
(Heated Oxygen Sensor)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (HT1B) - 2 (+B) 20°C (68°F) 9 to 14 Ω


If the result is not as specified, replace the heated oxygen sensor.