Home › Engine / Hybrid System › 3ZR-FE INTAKE / EXHAUST › EXHAUST PIPE › 2012.12–2015.10
RM3090E _51 Engine / Hybrid System _008408 3ZR-FE INTAKE / EXHAUST _0046967 EXHAUST PIPE A

3ZR-FE INTAKE / EXHAUST  EXHAUST PIPE  REMOVAL  


CAUTION / NOTICE / HINT

CAUTION:
·

Wear protective gloves when removing the exhaust pipe.

·

The exhaust pipe is extremely hot immediately after the engine has stopped.

·

Confirm that the exhaust pipe has cooled down before removing it.



PROCEDURE

Hide 89465 1.DISCONNECT HEATED OXYGEN SENSOR (for Bank 1 Sensor 2)

a.

Disconnect the grommet from the floor panel.


b.
A209091N01
2.292,0.844 1.979,0.219 1.979,0.219 2.229,0.219 true 2.271,0.146 2.729,0.344 0.458,0.198 10 SST

Using SST, loosen the heated oxygen sensor, and then disconnect the heated oxygen sensor by hand.

SST
09224-00010  

NOTICE:

Do not strike the metal part of the heated oxygen sensor.


HINT:

Rotate the heated oxygen sensor counterclockwise to disconnect it from the center exhaust pipe assembly, and record how many times it is rotated.



Hide 17430 2.REMOVE TAIL EXHAUST PIPE ASSEMBLY

a.

Remove the 2 bolts and 2 compression springs.


b.

Disconnect the 2 exhaust pipe supports and remove the tail exhaust pipe assembly.


c.

Remove the gasket from the center exhaust pipe assembly.

A293376


Hide 17420 3.REMOVE CENTER EXHAUST PIPE ASSEMBLY

a.

Remove the 2 bolts.


b.

Disconnect the 3 exhaust pipe supports and remove the center exhaust pipe assembly.


c.

Remove the gasket from the front exhaust pipe assembly.

A293377


Hide 17410 4.REMOVE FRONT EXHAUST PIPE ASSEMBLY

a.

Remove the 2 bolts, 2 compression springs and front exhaust pipe assembly.


b.

Remove the gasket from the exhaust manifold.

A207707