3ZR-FE BATTERY / CHARGING  GENERATOR  INSPECTION  


PROCEDURE

Hide 27415 1.INSPECT GENERATOR PULLEY WITH CLUTCH

a.
A211248
0.74,0.49 0.969,0.656 0.229,0.167 10 *1 2.573,0.49 2.844,0.656 0.271,0.167 10 *2
*1 Free
*2 Lock


Hold the center of the generator pulley with clutch, and confirm that the outer ring turns counterclockwise and does not turn clockwise.

If the result is not as specified, replace the generator pulley with clutch.


Hide 27370 2.INSPECT GENERATOR BRUSH HOLDER ASSEMBLY

a.
A128079
0.635,0.74 0.948,0.896 0.313,0.156 10 *1
*1 Length


Using a vernier caliper, measure the brush length.

Standard exposed length:

9.5 to 11.5 mm (0.374 to 0.453 in.)


Minimum exposed length:

4.5 mm (0.177 in.)


If the brush length is less than the minimum, replace the generator brush holder assembly.


Hide 27330 3.INSPECT GENERATOR ROTOR ASSEMBLY

a.

Check the generator rotor for an open circuit.

i.
A296802
0.667,1.146 0.292,0.792 0.292,0.792 0.781,1.104 true 0.115,0.708 0.427,0.865 0.313,0.156 10 *1
*1 Slip Ring


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Slip ring - Slip ring 20°C (68°F) 1.8 to 2.2 Ω


If the result is not as specified, replace the generator rotor assembly.



b.

Check the generator rotor for a short to ground.

i.
A296803
0.188,0.979 0.323,0.979 0.323,0.979 0.365,1.156 true 1.281,0.813 1.625,0.448 1.625,0.448 1.875,0.448 true 0.021,0.906 0.333,1.063 0.313,0.156 10 *1 1.906,0.365 2.219,0.521 0.313,0.156 10 *2
*1 Slip Ring
*2 Rotor


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Slip ring - Rotor Always 10 MΩ or higher


If the result is not as specified, replace the generator rotor assembly.



c.
A158899

Check that the bearing of the generator rotor is not rough or worn and that it rotates smoothly.

If necessary, replace the generator rotor assembly.


d.

Check each slip ring.

i.

Check that the slip rings are not rough or scored.

If the slip rings are rough or scored, replace the generator rotor assembly.


ii.
A124106
0.656,0.594 0.969,0.75 0.313,0.156 10 *1
*1 Diameter


Using a vernier caliper, measure the slip ring diameter.

Standard diameter:

14.2 to 14.8 mm (0.559 to 0.583 in.)


Minimum diameter:

14.0 mm (0.551 in.)


If the diameter is less than the minimum, replace the generator rotor assembly.