U660F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSAXLE SYSTEM  P0711  Transmission Fluid Temperature Sensor "A" Performance  


DESCRIPTION

The ATF temperature sensor converts the fluid temperature into a resistance value for use by the TCM.

The TCM applies a voltage to the temperature sensor through terminal THO1 of the TCM.

The sensor resistance changes with the ATF temperature. As the temperature becomes higher, the sensor resistance decreases.

One terminal of the sensor is grounded so that the sensor resistance decreases and the voltage goes down as the temperature becomes higher.

The TCM calculates the fluid temperature based on the voltage signal.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P0711 Transmission Fluid Temperature Sensor "A" Performance Either condition is met (2-trip detection logic):
·

Both (a) and (b) are detected:

·

(a) Intake air and engine coolant temperatures are -10°C (14°F) or higher at engine start

·

(b) After normal driving for over 18 min. and 20 sec. and 7 km (4.4 mile) or more, ATF temperature is below 20°C (68°F)


·

Both (a) and (b) are detected:

·

(a) Engine coolant temperature is below 35°C (95°F) at engine start

·

(b) ATF temperature is 110°C (230°F) or higher when engine coolant temperature reaches 60°C (140°F)



ATF temperature sensor (ATF temperature sensor assembly) Comes on DTC stored

MONITOR DESCRIPTION

This DTC indicates that there is a problem with output signals from the ATF temperature sensor and that the sensor itself is defective. The ATF temperature sensor converts the ATF temperature into an electrical resistance value. Based on the resistance, the TCM determines the ATF temperature and detects an open or short in the ATF temperature circuit or a fault of the ATF temperature sensor.

After running the vehicle for a certain period, the ATF temperature should increase. If the ATF temperature is below 20°C (68°F) after running the vehicle for a certain period, the TCM interprets this as a fault, turns on the MIL and stores the DTC.

CAUTION / NOTICE / HINT

NOTICE:

Perform registration and/or initialization when parts related to the automatic transaxle are replaced.

Click hereDrivetrain>U660F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSAXLE SYSTEM>PRECAUTION


DATA LIST


HINT:

Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


a.

Warm up the engine.


b.

Turn the ignition switch off.


c.

Connect the GTS to the DLC3.


d.

Turn the ignition switch to ON.


e.

Turn the GTS on.


f.

Enter the following menus: Powertrain / ECT / Data List.


g.

According to the display on the GTS, read the Data List.

Powertrain > ECT > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
A/T Oil Temperature 1 ATF temperature sensor value Min.: -40°C (-40°F)
Max.: 215°C (419°F)
·

After stall test: Approx. 80°C (176°F)

·

Equal to ambient temperature after cold soak


If the value is "-40°C (-40°F)" or "150°C (302°F)", the ATF temperature sensor circuit is open or shorted.
Powertrain > ECT > Data List
Tester Display
A/T Oil Temperature 1
50003 64 177
HINT:

When DTC P0712 is output and the GTS indicates 150°C (302°F) or higher, there is a short circuit.

When DTC P0713 is output and the GTS indicates -40°C (-40°F), there is an open circuit.

Check the temperature displayed on the GTS in order to check if a malfunction exists.


Temperature Displayed Malfunction
-40°C (-40°F) Open circuit
150°C (302°F) or higher Short circuit

If a circuit related to the ATF temperature sensor becomes open, P0713 is immediately stored (in 0.5 seconds). When P0713 is stored, P0711 cannot be stored.

It is not necessary to inspect the circuit when P0711 is stored.



PROCEDURE

1.CHECK DTC OUTPUT (IN ADDITION TO DTC P0711)
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / ECT / Trouble Codes.

Powertrain > ECT > Trouble Codes
50001 64

e.

Read the DTCs using the GTS.

Result:
Result Proceed to
Only P0711 is output A
P0711 and other DTCs are output B


HINT:

If any other codes besides P0711 are output, perform troubleshooting for those DTCs first.




A

2.CHECK TRANSAXLE FLUID LEVEL

B

2.CHECK TRANSAXLE FLUID LEVEL
a.

Check the transaxle fluid level.

Click hereDrivetrain>U660F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSAXLE FLUID>ADJUSTMENT

OK:

Automatic transaxle fluid level is correct.



Result:
Proceed to
OK
NG



OK

REPLACE ATF TEMPERATURE SENSOR (ATF TEMPERATURE SENSOR ASSEMBLY)

NG