Home › Drivetrain › U660F AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSAXLE SYSTEM
RM3090E _52 Drivetrain _008436 U660F AUTOMATIC TRANSMISSION / TRANSAXLE _0047080 AUTOMATIC TRANSAXLE SYSTEM C

U660F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSAXLE SYSTEM  P2716  Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)  


DESCRIPTION

Refer to DTC P2714.

Click hereDrivetrain>U660F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSAXLE SYSTEM>P2714

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT) An open or short is detected in the shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic).
·

Open or short in shift solenoid valve SLT circuit

·

Shift solenoid valve SLT

·

TCM


Comes on DTC stored

MONITOR DESCRIPTION

When an open or short in the shift solenoid valve SLT circuit is detected, the TCM interprets this as a fault. The TCM will turn on the MIL and store the DTC.

WIRING DIAGRAM

C279421
2.302,3.042 4.51,3.26 2.208,0.219 10 false Automatic Transaxle Assembly 1.042,2.5 3.406,2.74 2.365,0.24 10 false Transmission Valve Body Assembly 3.771,2.5 5.156,2.729 1.385,0.229 10 false Transmission Wire 5.604,1.25 6.167,1.448 0.563,0.198 10 false SLT+ 5.604,2.021 6.042,2.219 0.438,0.198 10 false SLT- 5.333,1.354 5.667,1.563 0.333,0.208 10 false 12 5.417,2.135 5.75,2.344 0.333,0.208 10 false 7 5.802,3.188 6.24,3.385 0.438,0.198 10 false TCM 1.563,1.646 5.229,1.844 3.667,0.198 10 false Shift Solenoid Valve SLT 1.135,1.229 1.469,1.438 0.333,0.208 10 false 1 1.135,2.042 1.469,2.25 0.333,0.208 10 false 2

CAUTION / NOTICE / HINT

NOTICE:

Perform registration and/or initialization when parts related to the automatic transaxle are replaced.

Click hereDrivetrain>U660F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSAXLE SYSTEM>PRECAUTION


PROCEDURE

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT)
a.
C207057
1.469,1.51 1.76,0.771 true 2.063,1.51 1.885,0.958 true 1.302,1.552 1.729,1.75 0.427,0.198 10 SLT- 1.948,1.552 2.375,1.75 0.427,0.198 10 SLT+ 0.604,0.229 0.917,0.427 0.313,0.198 10 *a
*a Component without TCM connected
(Transmission Wire)


Remove the TCM.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
12 (SLT+) - 7 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
12 (SLT+) - Body ground Always 10 kΩ or higher
7 (SLT-) - Body ground Always 10 kΩ or higher
12 (SLT+) - All other terminals except 7 (SLT-) Always 10 kΩ or higher
7 (SLT-) - All other terminals except 12 (SLT+) Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

NG

2.INSPECT SHIFT SOLENOID VALVE SLT
2.INSPECT SHIFT SOLENOID VALVE SLT
a.
C197715C16
1.75,1 2.208,0.365 false 1.49,1 1.052,0.365 false 1.76,2.948 2.208,2.354 false 1.51,2.948 1.052,2.354 false 0.135,0.208 0.448,0.406 0.313,0.198 10 *1 2.25,0.25 2.417,0.448 0.167,0.198 10 1 0.917,0.25 1.083,0.448 0.167,0.198 10 2 2.25,2.25 2.417,2.448 0.167,0.198 10 1 0.917,2.25 1.083,2.448 0.167,0.198 10 2 1.927,3.927 2.156,4.125 0.229,0.198 10 (+) 1.167,3.927 1.396,4.125 0.229,0.198 10 (-)
*1 Shift Solenoid Valve SLT


Remove shift solenoid valve SLT.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



c.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) with a 21 W bulb → Terminal 1

·

Battery negative (-) → Terminal 2


Valve moves and makes an operating noise



Result:
Proceed to
OK
NG



OK

NG