This circuit detects whether the ignition switch is ON or off, and sends this information to the main body ECU (multiplex network body ECU).
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
When replacing the main body ECU (multiplex network body ECU), make sure to replace it with a new one.
Using the GTS, read the Data List.
Click hereVehicle Interior>LIGHTING (INT)>LIGHTING SYSTEM>DATA LIST / ACTIVE TEST
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| IG SW | Ignition switch ON signal | ON or OFF | ON: Ignition switch ON
OFF: Ignition switch off |
"OFF" is also displayed for this item when the ignition switch is ACC. |
| Tester Display |
|---|
| IG SW |
The display is as specified in the normal condition column.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check the vehicle type.
| Proceed to |
|---|
| w/o Stop and Start System |
| w/ Stop and Start System |
w/o Stop and Start System
w/ Stop and Start System
| *a | Front view of wire harness connector
(to Instrument Panel Junction Block Assembly) |
Disconnect the instrument panel junction block assembly connectors.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3A-1 - Body ground | Always | 11 to 14 V |
| 3C-43 - Body ground | Ignition switch ON | 11 to 14 V |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3D-9 - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the 3C and 3D instrument panel junction block assembly connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3C-15 - 3D-40 | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the instrument panel junction block assembly.
for LHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU(for LHD)>REMOVAL
for RHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU(for RHD)>REMOVAL
Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
for LHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU(for LHD)>REMOVAL
for RHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU(for RHD)>REMOVAL
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3A-1 - 3C-15 | Battery voltage applied between terminals 3C-43 and 3D-9 | Below 1 Ω |
| Battery voltage not applied between terminals 3C-43 and 3D-9 | 10 kΩ or higher | |
| A-32 (IG) - 3D-40 | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
for LHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU(for LHD)>REMOVAL
for RHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU(for RHD)>REMOVAL
NG
for LHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU(for LHD)>REMOVAL
for RHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU(for RHD)>REMOVAL
| *a | Front view of wire harness connector
(to Instrument Panel Junction Block Assembly) |
Disconnect the instrument panel junction block assembly connectors.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 3D-40 - Body ground | Ignition switch ON | 10.5 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the instrument panel junction block assembly.
for LHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU(for LHD)>REMOVAL
for RHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU(for RHD)>REMOVAL
Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
for LHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU(for LHD)>REMOVAL
for RHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU(for RHD)>REMOVAL
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A-32 (IG) - 3D-40 | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
for LHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU(for LHD)>REMOVAL
for RHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU(for RHD)>REMOVAL
NG
for LHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU(for LHD)>REMOVAL
for RHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU(for RHD)>REMOVAL