33311
1.INSPECT INPUT SHAFT
Check the input shaft for wear and damage.
Using a dial indicator, measure the input shaft runout.
0.03 mm (0.00118 in.)
If the runout is more than the maximum, replace the input shaft.
Using a micrometer, measure the journal diameter at A and B on the input shaft.
| Measured Part | Specified Condition |
|---|---|
| Journal A | 30.008 to 30.020 mm (1.1815 to 1.1818 in.) |
| Journal B | 32.002 to 32.018 mm (1.2600 to 1.2605 in.) |
If the diameter is not as specified, replace the input shaft.