Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)
RM3090E _58 Vehicle Interior _008789 HEATING / AIR CONDITIONING _0049188 AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) U

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)  DATA LIST / ACTIVE TEST  


DATA LIST


Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Data List.


e.

Check the value(s) by referring to the table below.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Room Temperature Sensor Cooler (room temperature sensor) thermistor Min.: -6.50°C (-20.30°F)
Max.: 57.25°C (135.05°F)
Actual ambient temperature displayed -
Ambient Temp Sensor Cooler (ambient temperature sensor) thermistor Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F)
Actual ambient temperature displayed -
Adjusted Ambient Temp Adjusted ambient temperature Min.: -30.80°C (-23.44°F)
Max.: 50.80°C (123.44°F)
- -
Evaporator Fin Thermistor No. 1 cooler thermistor (evaporator temperature sensor) Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual evaporator temperature displayed -
Evaporator Target Temp Evaporator target temperature Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Evaporator target temperature displayed -
Solar Sensor (D Side) Driver side automatic light control sensor Min.: 0
Max.: 255
Driver side automatic light control sensor value increases as brightness increases -
Solar Sensor (P Side) Front passenger side automatic light control sensor Min.: 0
Max.: 255
Front passenger side automatic light control sensor value increases as brightness increases -
Engine Coolant Temp Engine coolant temperature sensor Min.: 1.30°C (34.34°F)
Max.: 90.55°C (194.99°F)
Actual engine coolant temperature displayed -
Set Temperature (D Side) Driver side set temperature Min.: MAX COLD
Max.: MAX HOT
Driver side set temperature displayed -
Set Temperature (P Side) Front passenger side set temperature Min.: MAX COLD
Max.: MAX HOT
Front passenger side set temperature displayed -
Blower Motor Speed Level Blower motor speed level Min.: 0
Max.: 31
Displayed speed level increases in range between 0 and 31 as blower motor speed increases -
Regulator Pressure Sensor Air conditioner pressure sensor Min.: -0.4566 MPaG
Max.: 3.2943 MPaG
Actual pressure displayed -
Regulator Control Current Solenoid valve control current Min.: 0 A
Max.: 0.997 A
Value changes between 0 A and 0.997 A in accordance with solenoid valve operation -
Air Mix Servo Targ Pulse(D) No. 2 air conditioning radiator damper servo sub-assembly (driver side air mix) target pulse Min.: 0
Max.: 255
for LHD:
MAX. COLD: 92 (pulse)
MAX. HOT: 5 (pulse)
for RHD:
MAX. COLD: 6 (pulse)
MAX. HOT: 93 (pulse)
-
Air Mix Servo Actual Pulse(D) No. 2 air conditioning radiator damper servo sub-assembly (driver side air mix) actual pulse Min.: 0
Max.: 255
for LHD:
MAX. COLD: 92 (pulse)
MAX. HOT: 5 (pulse)
for RHD:
MAX. COLD: 6 (pulse)
MAX. HOT: 93 (pulse)
-
Air Mix Servo Targ Pulse(P) No. 3 air conditioning radiator damper servo sub-assembly (front passenger side air mix) target pulse Min.: 0
Max.: 255
for LHD:
MAX. COLD: 6 (pulse)
MAX. HOT: 93 (pulse)
for RHD:
MAX. COLD: 92 (pulse)
MAX. HOT: 5 (pulse)
-
Air Mix Servo Actual Pulse(P) No. 3 air conditioning radiator damper servo sub-assembly (front passenger side air mix) actual pulse Min.: 0
Max.: 255
for LHD:
MAX. COLD: 6 (pulse)
MAX. HOT: 93 (pulse)
for RHD:
MAX. COLD: 92 (pulse)
MAX. HOT: 5 (pulse)
-
Air Outlet Servo Pulse (D) No. 1 air conditioning radiator damper servo sub-assembly (mode) target pulse Min.: 0
Max.: 255
FACE: 47 (pulse)
B/L: 37 (pulse)
FOOT: 17 (pulse)
FOOT/DEF: 9 (pulse)
DEF: 5 (pulse)
-
Air Outlet Servo Actu Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (mode) actual pulse Min.: 0
Max.: 255
FACE: 47 (pulse)
B/L: 37 (pulse)
FOOT: 17 (pulse)
FOOT/DEF: 9 (pulse)
DEF: 5 (pulse)
-
Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly (air inlet) target pulse Min.: 0
Max.: 255
for LHD:
RECIRCULATION: 19 (pulse)
FRESH: 7 (pulse)
for RHD:
RECIRCULATION: 7 (pulse)
FRESH: 19 (pulse)
-
Air Inlet Damper Actual Pulse No. 1 blower damper servo sub-assembly (air inlet) actual pulse Min.: 0
Max.: 255
for LHD:
RECIRCULATION: 19 (pulse)
FRESH: 7 (pulse)
for RHD:
RECIRCULATION: 7 (pulse)
FRESH: 19 (pulse)
-
Electric Heater Count Electric (PTC) heater count Min.: 0
Max.: 3
Actual number of the heater elements to be heated displayed w/ PTC Heater
Electric Heater Active Level Actual electric (PTC) operation level Min.: 0
Max.: 3
Actual number of the heater elements to be heated displayed w/ PTC Heater
Shift Set Temperature Shift set temperature 2C decr, 1C decr, Normal, 1C incr, 2C incr Customized value displayed -
Air Inlet Mode Air inlet mode Auto or Manual Customized value displayed
Customized value displayed
-
Compressor Mode Compressor mode Auto or Manual Customized value displayed -
Evaporator Control Evaporator Control Auto or Manual Customized value displayed -
ECO MODE Cancel ECO run cancel switch input signal ON or OFF Customized value displayed -
ECO Switch ECO mode switch input signal ON or OFF Customized value displayed -
Refrigerant Shortage Check Refrigerant gas volume check ON or OFF Customized value displayed -
Fan speed increment control Fan speed increment control Slow, Normal, Fast Customized value displayed -
Foot/DEF Auto Mode Foot/DEF Auto Mode ON or OFF Customized value displayed -
Foot/DEF Auto Blow Up Foot/DEF Auto blower speed increase ON or OFF Customized value displayed -
A/C Cutoff Signal The ECM sends the air conditioning control cut-off signal to the air conditioning amplifier assembly via CAN communication. OFF or ON OFF: The ECM does not send the air conditioning control cut-off signal
ON: The ECM sends the air conditioning control cut-off signal
-
Refrigerant Gas Type Refrigerant gas type R134a or 1234yf Refrigerant gas type displayed -
Blower Operation Setting (Stop&Start) Blower level to be 1, when Stop and Start control operate Blower off, Blower Level1 Customized valve displayed -
Number of Trouble Codes Number of trouble codes Min.: 0
Max.: 255
Number of DTCs displayed -


ACTIVE TEST


Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.

a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Active Test.


e.

Check the operation by referring to the table below.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Blower Motor Blower with fan motor sub-assembly Min.: 0, Max.: 31 -
Magnetic Clutch Relay Air conditioning system operation OFF, ON w/ Magnet Clutch
Defogger Relay (Rear) Defogger relay (engine room junction block assembly) OFF, ON -
Heater Active Level Heater active level Min.: 0, Max.: 3 -
Air Mix Servo Targ Pulse(D) No. 2 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse Min.: 0, Max.: 255 for LHD:
Operates between 5 and 92 pulses
for RHD:
Operates between 6 and 93 pulses
Air Mix Servo Targ Pulse(P) No. 3 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse Min.: 0, Max.: 255 for LHD:
Operates between 6 and 93 pulses
for RHD:
Operates between 5 and 92 pulses
Air Outlet Servo Pulse (D) No. 1 air conditioning radiator damper servo sub-assembly (mode) pulse Min.: 0, Max.: 255 Operates between 5 and 47 pulses
Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly (air inlet) target pulse Min.: 0, Max.: 255 Operates between 7 and 19 pulses