Home › Engine / Hybrid System › 3ZR-FE INTAKE / EXHAUST › VACUUM SWITCHING VALVE(for ACIS)
RM3090E _51 Engine / Hybrid System _008408 3ZR-FE INTAKE / EXHAUST _0049232 VACUUM SWITCHING VALVE(for ACIS) G

3ZR-FE INTAKE / EXHAUST  VACUUM SWITCHING VALVE(for ACIS)  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 17650G 1.INSPECT VACUU SWITCHING VALVE (for ACIS)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 27 to 33 Ω
1 - Body ground Always 1 MΩ or higher
2 - Body ground


If the result is not as specified, replace the vacuum switching valve.


b.
A205682
2.229,4.021 2.229,3.677 2.229,3.677 1.979,3.438 true 0.771,3.146 0.927,3.302 0.156,0.156 10 E 2.135,4.063 2.281,4.229 0.146,0.167 10 *1
*1 Filter
V100135

Air


Check the VSV operation.

i.

When vacuum is applied to port E, check that air is sucked into the filter.


ii.
A205683
1.083,4.198 1.083,3.958 1.083,3.958 1.333,3.052 true 1.417,3.073 1.771,4.063 1.771,4.063 2.01,4.063 true 1.01,3.052 1.188,3.229 0.177,0.177 10 E 0.719,3.75 0.833,3.938 0.115,0.188 10 F 1.052,4.229 1.208,4.427 0.156,0.198 10 1 2.052,3.99 2.208,4.188 0.156,0.198 10 2
V100135

Air


Apply battery voltage to the terminals as shown in the illustration. When vacuum is applied to port F, check that air is sucked into port E.

If the result is not as specified, replace the vacuum switching valve.