25860
1.INSPECT NO. 1 VACUUM SWITCHING VALVE ASSEMBLY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 28.3 to 31.1 Ω |
|
Air |
Check No. 1 vacuum switching valve assembly operation.
Check that air does not flow from port A to port B.
|
Air |
Apply battery voltage across terminals 1 and 2 as shown in the illustration.
Check that air flows from port A to port B.
If the result is not as specified, replace the No. 1 vacuum switching valve assembly.