25819
1.INSPECT VACUUM REGULATING VALVE ASSEMBLY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 11.1 to 12.5 Ω |
If the result is not as specified, replace the vacuum regulating valve assembly.
Inspect vacuum regulating valve operation.
|
Air |
Check that air flows from port E to G.
| *1 | Filter |
|
Air |
Apply battery voltage across terminals 1 and 2 as shown in the illustration.
Check that air flows from port E to the filter.
If the result is not as specified, replace the vacuum regulating valve assembly.