When the theft deterrent system is switched from the armed state to the alarm sounding state, the main body ECU (multiplex network body ECU) transmits a signal to cause the security horn to sound at intervals of 0.4 seconds.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
When replacing the main body ECU (multiplex network body ECU), make sure to replace it with a new one.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Main Body / Active Test.
According to the display on the GTS, perform the Active Test.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Security Horn | Security indicator | ON or OFF | - |
| Tester Display |
|---|
| Security Horn |
The security horn assembly sounds and stops correctly when operated through the GTS.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the security horn assembly.
Click hereVehicle Interior>THEFT DETERRENT / KEYLESS ENTRY>SECURITY HORN ASSEMBLY>REMOVAL
Inspect the security horn assembly.
Click hereVehicle Interior>THEFT DETERRENT / KEYLESS ENTRY>SECURITY HORN ASSEMBLY>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the security horn relay.
Measure the resistance according to the value(s) in the table below
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage is applied between terminals 2 - 1 | Below 1 Ω |
| 3 - 5 | Battery voltage is not applied between terminals 2 - 1 | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the main body ECU (multiplex network body ECU).
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU(for LHD)>REMOVAL
Connect the instrument panel junction block assembly connectors.
Remove the security horn relay.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 - A-17 (SH) | Always | Below 1 Ω |
| 2 - Body ground | Always | 10 kΩ or higher |
| A-17 (SH) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the security horn relay.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - Body ground | Always | 11 to 14 V |
| 5 - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the security horn relay.
Disconnect the A13 security horn assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - A13-1 | Always | Below 1 Ω |
| A13-2 - Body ground | Always | Below 1 Ω |
| 3 - Body ground | Always | 10 kΩ or higher |
| A13-1 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the 3D instrument panel junction block assembly connector.
Remove the security horn relay.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 - 3D-53 | Always | Below 1 Ω |
| 2 - Body ground | Always | 10 kΩ or higher |
| 3D-53 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG