Home › Engine / Hybrid System › 3ZR-FAE STARTING › STARTER › 2012.12–2016.08
RM3090E _51 Engine / Hybrid System _008393 3ZR-FAE STARTING _0049596 STARTER G

3ZR-FAE STARTING  STARTER  INSPECTION  


PROCEDURE

Hide 28100 1.INSPECT STARTER ASSEMBLY

CAUTION:

As a large electric current passes through the cable during this inspection, a thick cable must be used. Otherwise, the cable may become hot and cause injury.


NOTICE:

These tests must be performed eithin 3 to 5 seconds to prevent the coil from burning out.


a.

Mount the starter assembly in a vise between aluminum plates.

i.
A156605
1.094,0.792 1.198,0.792 1.198,0.792 1.406,1.26 false 2.427,1.635 1.792,2.323 false 2.677,1.469 2.75,1.052 2.75,1.052 2.833,1.052 false 0.906,0.698 1.219,0.854 0.313,0.156 10 *1 1.604,2.208 1.917,2.365 0.313,0.156 10 *2 2.885,0.948 3.198,1.104 0.313,0.156 10 *3
*1 Body
*2 Terminal C
*3 Terminal 50


Remove the nut and disconnect the lead wire from terminal C.


ii.

Connect the battery to the magnet starter switch assembly as shown in the illustration. Check that the clutch pinion gear is extended.

If the clutch pinion gear does not move, replace the magnet starter switch assembly.



b.

Perform a holding test.

i.
A156606
2.427,1.635 1.792,2.323 false 1.396,1.281 1.125,0.76 false 2.677,1.469 2.969,1.156 false 0.948,0.625 1.26,0.781 0.313,0.156 10 *1 1.625,2.333 1.938,2.49 0.313,0.156 10 *2 2.938,0.99 3.25,1.146 0.313,0.156 10 *3
*1 Body
*2 Terminal C
*3 Terminal 50


When the battery is connected as shown above with the clutch pinion gear out, disconnect the negative (-) lead from terminal C. Check that the pinion gear remains out.

If the clutch pinion gear returns inward, replace the magnet starter switch assembly.



c.

Check the operation.

i.
A156607
2.427,1.635 1.792,2.323 false 1.396,1.281 1.125,0.76 false 2.688,1.479 2.969,1.156 false 0.979,0.594 1.292,0.75 0.313,0.156 10 *1 1.677,2.333 1.99,2.49 0.313,0.156 10 *2 2.979,0.958 3.292,1.115 0.313,0.156 10 *3
*1 Body
*2 Terminal C
*3 Terminal 50


Disconnect the negative (-) lead from the starter body. Check that the clutch pinion gear returns.

If the clutch pinion gear does not return inward, replace the magnet starter switch assembly.



d.

Perform an operation test without load.

i.

Connect the lead wire to terminal C with the nut.

Torque:
9.8 N*m (100 kgf*cm, 87 in.*lbf)


ii.
A197934
1.76,2.698 2.292,1.583 2.292,1.583 2.479,1.552 false 1.031,0.948 1.375,1.302 false 2.708,2.875 2.698,2.542 2.698,2.542 2.615,1.729 false 0.865,0.781 1.177,0.938 0.313,0.156 10 *1 2.635,2.875 2.948,3.031 0.313,0.156 10 *2 1.635,2.708 1.948,2.865 0.313,0.156 10 *3
*1 Body
*2 Terminal 50
*3 Terminal 30


Connect the battery and an ammeter to the starter assembly as shown in the illustration.


iii.

Check that the starter assembly rotates smoothly and steadily while pinion gear is moving out. Then measure the current.

Standard current:

90 A or less at 11.5 V


If the result is not as specified, replace the starter assembly.



Hide 28160 2.INSPECT STARTER ARMATURE ASSEMBLY

A122065

a.

Check the commutator for open circuits.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Segment - Segment Always Below 1 Ω


If the result is not as specified, replace the starter armature assembly.



b.
A122066

Check the commutator for ground.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Segment - Coil Core Always Below 1 Ω


If the result is not as specified, replace the starter armature assembly.



c.

Check the commutator surface for dirt and burns.

If the surface is dirty or burnt, restore it with sandpaper (No. 400) or a lathe.


d.
A122067

Check the commutator for circle runout.

i.

Place the commutator on V-blocks.


ii.

Using a dial indicator, measure the circle runout.

Maximum Runout:

0.05 mm (0.00196 in.)


If the runout is more than the maximum, replace the starter armature assembly.



e.
A122068

Using a vernier caliper, measure the commutator diameter.

Standard Diameter:

28.0 mm (1.10 in.)


Minimum Diameter:

27.0 mm (1.06 in.)


If the diameter is less than the minimum, replace the starter armature assembly.


f.
A158859

Check that the undercut portion between the segments is free of foreign matter and measure its depth.

Standard Undercut Depth:

0.6 mm (0.0236 in.)


Minimum Undercut Depth:

0.2 mm (0.00787 in.)


If the undercut depth is less than the minimum, adjust it with a hacksaw blade.


Hide 28120 3.INSPECT STARTER YOKE ASSEMBLY

A158860
1.427,0.875 1.073,0.875 false 1.625,0.51 1.688,0.51 1.688,0.51 2.25,1 false 1.448,0.427 1.76,0.583 0.313,0.156 10 *1 0.906,0.781 1.219,0.938 0.313,0.156 10 *2
*1 Field Coil Brush Lead
*2 Terminal C


a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Terminal C - Brush lead Always Below 1 Ω


If the result is not as specified, replace the starter yoke assembly.


b.
A158861
1.792,0.49 1.854,0.49 1.854,0.49 2.385,1 false 1.156,1.24 1.229,1.24 1.229,1.24 1.677,1.646 false 1.625,0.417 1.938,0.573 0.313,0.156 10 *1 0.969,1.125 1.281,1.281 0.313,0.156 10 *2
*1 Field Coil Brush Lead
*2 Starter Yoke Body


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Brush lead - Body Always 10 kΩ or higher


If the result is not as specified, replace the starter yoke assembly.


Hide 4.INSPECT BRUSH

a.
A300699

Using a vernier caliper, measure the brush length.

Standard Length:

14 mm (0.551 in.)


Minimum Length:

9 mm (0.354 in.)


If the length is less than the minimum, replace the starter brush holder assembly and the starter yoke assembly.


Hide 28140 5.INSPECT STARTER BRUSH HOLDER ASSEMBLY

a.
A153747
2.313,0.083 2.26,0.083 2.26,0.083 1.969,0.615 false 2.281,1.646 2.188,1.646 2.188,1.646 2,1.302 false 1.135,0.625 0.844,0.271 0.844,0.271 0.74,0.271 false 1.115,1.281 0.563,1.417 0.563,1.417 0.469,1.417 false 2.365,1.542 2.573,1.719 0.208,0.177 10 (+) 2.333,0 2.51,0.177 0.177,0.177 10 (-) 0.448,0.167 0.656,0.344 0.208,0.177 10 (+) 0.25,1.292 0.427,1.469 0.177,0.177 10 (-)

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Positive (+) brush holder - Negative (-) brush holder Always 10 kΩ or higher


If the result is not as specified, replace the starter brush holder assembly.


Hide 28021 6.INSPECT STARTER CENTER BEARING CLUTCH SUB-ASSEMBLY

A158862
1.438,0.219 1.75,0.375 0.313,0.156 10 *a 1.448,1.635 1.76,1.792 0.313,0.156 10 *b
*a Free
*b Lock


a.

Hold the starter clutch and rotate the pinion gear clockwise, and check that it turns freely. Try to rotate the pinion gear counterclockwise and check that it locks.

If the result is not as specified, replace the starter center bearing clutch sub-assembly.


Hide 28150 7.INSPECT MAGNET STARTER SWITCH ASSEMBLY

A300700

a.

Check the plunger.

i.

Push in the plunger and check that it returns quickly to its original position.

If the result is not as specified, replace the magnet starter switch assembly.



b.
A156363
1.688,1.448 2.083,1.719 false 1.625,1.427 2.083,1.719 false 1.583,1.094 0.823,0.573 false 2.115,1.635 2.479,1.813 0.365,0.177 10 *2 0.635,0.5 0.948,0.656 0.313,0.156 10 *1
*1 Terminal 50
*2 Terminal C


Check the pull-in coil for an open circuit.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Terminal 50 - Body Always Below 1 Ω


If the result is not as specified, replace the magnet starter switch assembly.



c.
A156364
1.958,1.396 1.958,1.594 false 1.323,1.094 0.76,0.542 false 0.563,0.469 0.906,0.615 0.344,0.146 10 *1 1.875,1.604 2.219,1.771 0.344,0.167 10 *2
*1 Terminal 50
*2 Magnet Starter Switch Body


Check whether the holding coil has an open circuit.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Terminal 50 - Body Always Below 2 Ω


If the result is not as specified, replace the magnet starter switch assembly.