Home › Power Source / Network › 1AD-FTV BATTERY / CHARGING › GENERATOR › 2012.12–2015.10
RM3090E _57 Power Source / Network _008779 1AD-FTV BATTERY / CHARGING _0049700 GENERATOR A

1AD-FTV BATTERY / CHARGING  GENERATOR  REASSEMBLY  


PROCEDURE

Hide 27310B 1.INSTALL GENERATOR DRIVE END FRAME BEARING

a.
A196742E01
2.783,0.494 3.092,0.655 0.309,0.161 10 SST 1.974,1.133 2.44,1.133 2.44,1.133 2.44,0.596 false 1.866,0.596 2.754,0.596 false

Using SST and a press, press in a new generator drive end frame bearing.

SST
09950-60010  (09951-00470)
09950-70010  (09951-07100)


b.

Install the retainer plate with the 4 screws.

Torque:
2.3 N*m (23 kgf*cm, 20 in.*lbf)


Hide 27330 2.INSTALL GENERATOR ROTOR ASSEMBLY

a.

Place the generator drive end frame assembly on the generator pulley with clutch.


b.

Install the generator rotor assembly to the generator drive end frame assembly.


c.

Install a new washer to the generator rotor assembly.


Hide 27360 3.INSTALL GENERATOR COIL ASSEMBLY

a.
A196746

Using a 21 mm deep socket wrench and press, slowly press in the generator coil assembly.


b.

Install the generator coil assembly with the 4 bolts.

Torque:
5.9 N*m (60 kgf*cm, 52 in.*lbf)


Hide 27370 4.INSTALL GENERATOR BRUSH HOLDER ASSEMBLY

a.
A158992C13
1.021,0.708 1.448,0.177 1.448,0.177 1.604,0.177 false 1.646,0.104 1.958,0.26 0.313,0.156 10 *1
*1 Pin


While pushing the 2 brushes into the generator brush holder assembly, insert a pin with a diameter of 1.0 mm (0.0394 in.) into the brush holder hole.


b.
A297150C01
1.667,1.167 2.167,0.417 2.167,0.417 2.333,0.417 true 2.375,0.354 2.688,0.51 0.313,0.156 10 *1
*1 Pin


Install the generator brush holder assembly with the 2 screws.

Torque:
1.8 N*m (18 kgf*cm, 16 in.*lbf)


c.

Pull out the pin from the generator brush holder assembly.


Hide 27387 5.INSTALL TERMINAL INSULATOR

a.

Install the terminal insulator to the generator coil assembly.


Hide 27039 6.INSTALL GENERATOR REAR END COVER

a.

Install the generator rear end cover with the 3 nuts.

Torque:
4.6 N*m (47 kgf*cm, 41 in.*lbf)


Hide 27415 7.INSTALL GENERATOR PULLEY WITH CLUTCH

a.

Temporarily install the generator pulley with clutch.


b.

Mount the generator in a vise between aluminum plates.


c.
A297151C01
0.333,1.333 0.333,0.833 true 1.333,1.375 1.5,1.375 1.5,1.375 1.667,0.917 true 1.583,1.833 1.75,1.833 1.75,1.833 2.083,1.25 true 1.042,0.615 1.354,0.771 0.313,0.156 10 false *1 0.052,1.375 0.604,1.521 0.552,0.146 10 false SST (A) 0.833,1.302 1.375,1.448 0.542,0.146 10 false SST (A) 1.073,1.75 1.615,1.917 0.542,0.167 10 false SST (B)
*1 Generator Rotor Shaft


Install SST (A) and (B) to the generator pulley with clutch as shown in the illustration.

NOTICE:

Securely install SST to the generator pulley with clutch and generator rotor shaft.


SST
09820-63021  


d.
A297152C01
0.979,1.042 0.729,1.042 true 1.229,0.771 1.146,0.438 1.146,0.438 0.896,0.438 true 0.75,2.479 1.063,2.635 0.313,0.156 10 false *1 1.167,2.073 1.479,2.229 0.313,0.156 10 false *a 0.219,0.948 0.99,1.146 0.771,0.198 10 false SST (A) 0.375,0.354 0.917,0.521 0.542,0.167 10 false SST (B)
*1 Fulcrum Length
*a Hold
V100135

Turn


Using a wrench to hold SST (A), turn SST (B) clockwise to tighten the generator pulley with clutch.

Torque:
without SST : 111 N*m (1132 kgf*cm, 82 ft.*lbf)
with SST : 88 N*m (897 kgf*cm, 65 ft.*lbf)

NOTICE:

Be careful as the generator pulley with clutch or rotor shaft may be damaged if the position of SST is not securely maintained while performing this operation.


HINT:
·

Use a torque wrench with a fulcrum length of 400 mm (15.7 in.). When using a torque wrench with a fulcrum length that is not 400 mm (15.7 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION

·

Make sure SST and the wrench are connected in a straight line.




e.

Remove SST from the generator assembly.


f.

Check that the generator pulley with clutch rotates smoothly.


Hide 27416 8.INSTALL GENERATOR PULLEY CAP

a.

Install a new generator pulley cap.