HEATING / AIR CONDITIONING  BLOWER RESISTOR  INSPECTION  


PROCEDURE

Hide 87138C 1.INSPECT BLOWER RESISTOR

a.
E145426
1.979,1.167 2.427,0.896 true 1.479,1.177 1.01,0.885 true 1.979,1.552 2.448,1.781 true 1.479,1.552 1.01,1.76 true 0.375,0.229 0.823,0.656 0.448,0.427 10 *a 2.49,0.635 2.906,0.823 0.417,0.188 10 *A: HI 0.51,0.667 0.979,0.865 0.469,0.198 10 *A: M1 2.51,1.646 2.969,1.844 0.458,0.198 10 *A: M2 0.531,1.646 0.99,1.833 0.458,0.188 10 *A: LO 0.521,0.844 0.99,1.042 0.469,0.198 10 *B: M2 2.49,0.823 2.938,1.021 0.448,0.198 10 *B: LO 0.542,1.823 0.938,2 0.396,0.177 10 *B: HI 2.521,1.813 3.042,2.021 0.521,0.208 10 *B: M1
*A for LHD
*B for RHD
*a Component without harness connected
(Blower Resistor)


Measure the resistance according to the value(s) in the table below.

Standard Resistance for LHD:
Tester Connection Condition Specified Condition
4 (LO) - 1 (HI) Always 3.12 to 3.60 Ω
2 (M1) - 1 (HI) Always 1.45 to 1.67 Ω
3 (M2) - 1 (HI) Always 0.52 to 0.60


Standard Resistance: for RHD:
Tester Connection Condition Specified Condition
1 (LO) - 4 (HI) Always 3.12 to 3.60 Ω
3 (M1) - 4 (HI) Always 1.45 to 1.67 Ω
2 (M2) - 4 (HI) Always 0.52 to 0.60


If the result is not as specified, replace the blower resistor.