Home › Engine / Hybrid System › 3ZR-FAE COOLING › RELAY
RM3090E _51 Engine / Hybrid System _008391 3ZR-FAE COOLING _0046842 RELAY G

3ZR-FAE COOLING  RELAY  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 85927 1.INSPECT NO. 1 COOLING FAN RELAY (FAN NO. 1)

a.
B060778
2.604,0.698 2.958,0.5 true 2.458,1.135 2.958,0.917 true 2.448,1.635 2.948,1.375 true 2.031,0.667 1.719,0.51 true 3,0.396 3.115,0.594 0.115,0.198 10 2 3.01,0.833 3.125,1.031 0.115,0.198 10 5 2.99,1.292 3.104,1.49 0.115,0.198 10 3 1.583,0.406 1.698,0.604 0.115,0.198 10 1 0.229,1.313 0.344,1.51 0.115,0.198 10 1 1.167,0.771 1.281,0.969 0.115,0.198 10 5 0.229,0.771 0.344,0.969 0.115,0.198 10 3 1.177,1.302 1.292,1.5 0.115,0.198 10 2

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the No. 1 cooling fan relay.


Hide 85927A 2.INSPECT NO. 2 COOLING FAN RELAY (FAN NO. 2)

a.
A159206
2.031,0.646 1.875,0.521 1.875,0.521 1.708,0.521 true 2.427,1.125 3.01,1.125 true 2.396,1.625 3.021,1.625 true 2.948,0.5 2.781,0.5 2.781,0.5 2.615,0.667 true 2.646,0.167 2.479,0.167 2.479,0.167 2.313,0.667 true 0.24,0.938 0.396,1.115 0.156,0.177 10 5 0.229,1.333 0.385,1.51 0.156,0.177 10 1 0.708,0.406 0.948,0.563 0.24,0.156 10 4 1.135,0.917 1.292,1.094 0.156,0.177 10 3 1.146,1.323 1.302,1.5 0.156,0.177 10 2 1.604,0.448 1.76,0.625 0.156,0.177 10 1 2.688,0.094 2.844,0.271 0.156,0.177 10 4 3,0.427 3.156,0.604 0.156,0.177 10 2 3.063,1.563 3.219,1.74 0.156,0.177 10 3 3.042,1.052 3.198,1.229 0.156,0.177 10 5

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 4 Battery voltage not applied between terminals 1 and 2 Below 1 Ω
Battery voltage applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher
Battery voltage applied between terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the No. 2 cooling fan relay.


Hide 85927B 3.INSPECT NO. 3 COOLING FAN RELAY (FAN NO. 3)

a.
B060778
2.604,0.698 2.958,0.5 true 2.458,1.135 2.958,0.917 true 2.448,1.635 2.948,1.375 true 2.031,0.667 1.719,0.51 true 3,0.396 3.115,0.594 0.115,0.198 10 2 3.01,0.833 3.125,1.031 0.115,0.198 10 5 2.99,1.292 3.104,1.49 0.115,0.198 10 3 1.583,0.406 1.698,0.604 0.115,0.198 10 1 0.229,1.313 0.344,1.51 0.115,0.198 10 1 1.167,0.771 1.281,0.969 0.115,0.198 10 5 0.229,0.771 0.344,0.969 0.115,0.198 10 3 1.177,1.302 1.292,1.5 0.115,0.198 10 2

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the No. 3 cooling fan relay.