Home › Vehicle Exterior › WINDOW / GLASS › POWER WINDOW CONTROL SYSTEM(w/ Jam Protection Function)
RM3090E _59 Vehicle Exterior _008792 WINDOW / GLASS _0050246 POWER WINDOW CONTROL SYSTEM(w/ Jam Protection Function) J

WINDOW / GLASS  POWER WINDOW CONTROL SYSTEM(w/ Jam Protection Function)  Auto Up Operation does not Fully Close Power Window (Jam Protection Function is Activated)  


DESCRIPTION

If the driver door glass or the front power window regulator motor assembly LH (for LHD) or front power window regulator motor assembly RH (for RHD) does not operate smoothly, the jam protection function may be triggered automatically, resulting in the auto up function being unable to fully close the window.

CAUTION / NOTICE / HINT

NOTICE:
·

If the front power window regulator motor assembly LH (for LHD) or front power window regulator motor assembly RH (for RHD) has been replaced with a new one, initialize the power window control system.

Click hereVehicle Exterior>WINDOW / GLASS>POWER WINDOW CONTROL SYSTEM(w/ Jam Protection Function)>INITIALIZATION

·

If the front power window regulator motor assembly LH (for LHD) or front power window regulator motor assembly RH (for RHD) has been removed and installed, or if the front power window regulator motor assembly LH (for LHD) or front power window regulator motor assembly RH (for RHD) was reused when the door glass or door glass run was replaced, initialize the power window control system.

Click hereVehicle Exterior>WINDOW / GLASS>POWER WINDOW CONTROL SYSTEM(w/ Jam Protection Function)>INITIALIZATION



PROCEDURE

1.PERFORM INITIALIZATION
a.

Initialize the front power window regulator motor assembly LH (for LHD) or front power window regulator motor assembly RH (for RHD).

Click hereVehicle Exterior>WINDOW / GLASS>POWER WINDOW CONTROL SYSTEM(w/ Jam Protection Function)>INITIALIZATION


Result:
Proceed to
NEXT



NEXT

2.CHECK POWER WINDOW CONTROL SYSTEM (AUTO UP/DOWN FUNCTION)
2.CHECK POWER WINDOW CONTROL SYSTEM (AUTO UP/DOWN FUNCTION)
a.

Check that the driver door power window moves when the auto up and down function of the power window regulator master switch assembly is operated.

Click hereVehicle Exterior>WINDOW / GLASS>POWER WINDOW CONTROL SYSTEM(w/ Jam Protection Function)>OPERATION CHECK

OK:

Driver door power window auto up and down function is normal.



Result:
Proceed to
OK
NG



OK

END (PROBLEM DUE TO INITIALIZATION FAILURE)

NG

3.CHECK WINDOW GLASS SLIDING MOVEMENT
3.CHECK WINDOW GLASS SLIDING MOVEMENT
a.

Remove the front door window regulator sub-assembly LH (for LHD) or front door window regulator sub-assembly RH (for RHD).


b.

Install the window glass to the door glass run.


c.

Check if the front door window regulator sub-assembly LH (for LHD) or front door window regulator sub-assembly RH (for RHD) operates smoothly.


d.

Check that the window glass slides smoothly when sliding it up by hand.

CAUTION:

Perform initialization again.


HINT:

Ensure the following:

·

The window glass fits with the glass run without improper contact or deformation.

·

Foreign matter is not caught in the glass run.




Result:
Proceed to
Door window glass and regulator slides smoothly (for LHD)
Door window glass and regulator slides smoothly (for RHD)
Door window glass slides or regulator not smoothly



Door window glass and regulator slides smoothly (for LHD)

REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH

Door window glass and regulator slides smoothly (for RHD)

REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH

Door window glass slides or regulator not smoothly

FIT WINDOW GLASS CORRECTLY (REMOVE FOREIGN MATTER CAUSING IMPROPER FIT OR REPLACE PARTS)