Home › Power Source / Network › 3ZR-FAE BATTERY / CHARGING › CHARGING SYSTEM › 2012.12–2015.04
RM3090E _57 Power Source / Network _008394 3ZR-FAE BATTERY / CHARGING _0046852 CHARGING SYSTEM C

3ZR-FAE BATTERY / CHARGING  CHARGING SYSTEM  P1602  Deterioration of Battery  


DESCRIPTION

The generator control ECU assembly monitors battery conditions. If the voltage drops below a certain value while the engine is running (not cranking), the generator control ECU assembly determines the battery is deteriorated and stores this DTC.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P1602 Deterioration of Battery Battery capacity is abnormally low for 10 seconds or more when the engine is running (not cranking)
(1 trip detection logic)
·

Battery

·

Wire harness or connector

·

ALT-S/ICS fuse


Does not come on DTC stored

CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses for circuits related to this system before performing the following inspection procedure.


PROCEDURE

1.CHECK CHARGING SYSTEM

Result:
Result
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)

NG

REPAIR OR REPLACE CHARGING SYSTEM

2.CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
a.
E259223C05
0.615,1.073 0.979,1.271 0.365,0.198 2.01,1.073 2.552,0.802 false 0.667,1.094 0.979,1.281 0.313,0.188 10 A58 2.615,0.708 3.042,0.906 0.427,0.198 10 AM21 0.167,0.146 0.479,0.344 0.313,0.198 10 *a
*a Front view of wire harness connector
(to Generator Control ECU Assembly)


Disconnect the A58 generator control ECU assembly connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A58-5 (AM21) - Body ground Always 11 to 14 V



Result:
Result
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR