Home › Power Source / Network › 2AD-FTV BATTERY / CHARGING › CHARGING SYSTEM
RM3090E _57 Power Source / Network _008780 2AD-FTV BATTERY / CHARGING _0051075 CHARGING SYSTEM U

2AD-FTV BATTERY / CHARGING  CHARGING SYSTEM  TERMINALS OF ECM  


TERMINAL INSPECTION


A194498
2.521,0.24 2.917,0.479 0.396,0.24 5.521,0.24 5.917,0.479 0.396,0.24 2.594,0.302 2.875,0.458 0.281,0.156 10 B76 5.604,0.292 5.885,0.438 0.281,0.146 10 A61

a.

Measure the voltage and resistance according to the value(s) in the table below.

HINT:

The standard voltage of each ECM terminal is shown in the table below.

In the table, first follow the information in "Condition". Look at "Terminal No. (Symbol)" for the terminals to be inspected. The standard voltage between the terminals is shown in "Specified Condition".

Use the illustration above as a reference for the ECM terminals.


Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
B76-55 (RLO) - B76-109 (E1) R - BR Generator After engine warmed up, during charging control, vehicle accelerated Pulse generation
(see waveform 1)
B76-55 (RLO) - B76-109 (E1) R - BR Generator After engine warmed up, during charging control, vehicle decelerated Pulse generation
(see waveform 2)
B76-75 (VCIB) - B76-77 (EIB) GR - L Battery current sensor assembly Ignition switch ON 4.5 to 5.5 V
B76-115 (THB) - B76-77 (EIB) W - L Battery current sensor assembly Ignition switch ON 0.2 to 4.8 V
B76-116 (IB) - B76-77 (EIB) R - L Wiper operation signal Ignition switch ON,
battery thermometer sensor surrounding temperature -30 to 90°C (-22 to 194°F)
0.2 to 4.8 V
B76-109 (E1) - Body ground BR - Body ground Ground circuit of ECM Always Below 1 Ω
A61-2 (BATT) - B76-109 (E1) W - BR Battery (for measuring the battery voltage and for the ECM memory) Always 11 to 14 V


b.
A287459
2.948,1.667 3.406,1.865 0.458,0.198 10 GND 2.667,0.302 3.313,0.51 0.646,0.208 10 2 V/DIV. 0.833,1.958 1.708,2.177 0.875,0.219 10 50 ms./DIV.

Using an oscilloscope, check waveform 1.

Waveform 1:
Item Content
Terminal No. (Symbol) B76-55 (RLO) - B76-109 (E1)
Tool Setting 2 V/DIV., 50 ms./DIV.
Condition After engine warmed up, during charging control, vehicle accelerated


HINT:

A constant value is not output, as the duty ratio varies depending on the electrical load and battery condition.



c.
A287460
2.958,1.677 3.417,1.875 0.458,0.198 10 GND 2.708,0.344 3.406,0.583 0.698,0.24 10 2 V/DIV. 0.948,1.979 1.802,2.167 0.854,0.188 10 50 ms./DIV.

Using an oscilloscope, check waveform 2.

Waveform 2:
Item Content
Terminal No. (Symbol) B76-55 (RLO) - B76-109 (E1)
Tool Setting 2 V/DIV., 50 ms./DIV.
Condition After engine warmed up, during charging control, vehicle decelerated


HINT:

A constant value is not output, as the duty ratio varies depending on the electrical load and battery condition.