Home › Engine / Hybrid System › 2AD-FHV COOLING › COOLING FAN MOTOR › 2012.12–2015.10
RM3090E _51 Engine / Hybrid System _008738 2AD-FHV COOLING _0050224 COOLING FAN MOTOR G

2AD-FHV COOLING  COOLING FAN MOTOR  INSPECTION  


PROCEDURE

Hide 16363 1.INSPECT COOLING FAN MOTOR

A208241C01
1.438,0.542 1.771,0.802 0.333,0.26 0.552,0.24 0.823,0.24 0.823,0.24 1.01,0.51 true 0.51,1.073 0.781,1.073 0.781,1.073 1,0.792 true 0.052,0.031 0.365,0.188 0.313,0.156 10 *a 1.458,0.594 1.917,0.792 0.458,0.198 10 A52 0.427,0.135 0.688,0.313 0.26,0.177 10 1 0.406,0.969 0.667,1.146 0.26,0.177 10 2
*a Component without harness connected
(Cooling Fan Motor)


a.

Disconnect the cooling fan motor connector.


b.

Check that the fan rotates smoothly by hand.


c.

Check that the motor turns smoothly when the battery is connected to the cooling fan motor connector.


d.

Measure the current according to the value(s) in the table below.

Standard Current:
Tester Connection Condition Specified Condition
A52 - 2 Motor is turning at 20°C (68°F) when battery voltage is 12 V 10.6 to 16.6 A


If the result is not as specified, replace the cooling fan motor.


e.

Reconnect the cooling fan motor connector.


Hide 16363A 2.INSPECT NO. 2 COOLING FAN MOTOR

A299155C01
1.573,0.458 1.896,0.656 0.323,0.198 2.458,0.5 2.604,0.156 2.604,0.156 2.823,0.156 true 2.469,0.75 2.719,1.042 2.719,1.042 2.938,1.042 true 0.031,0.031 0.344,0.188 0.313,0.156 10 *a 1.615,0.479 2.073,0.677 0.458,0.198 10 A51 2.875,0.052 3.063,0.24 0.188,0.188 10 1 3.021,0.927 3.208,1.115 0.188,0.188 10 2
*a Component without harness connected
(No. 2 Cooling Fan Motor)


a.

Disconnect the No. 2 cooling fan motor connector.


b.

Check that the fan rotates smoothly by hand.


c.

Check that the motor turns smoothly when the battery is connected to the No. 2 cooling fan motor connector.


d.

Measure the current according to the value(s) in the table below.

Standard Current:
Tester Connection Condition Specified Condition
A51 - 1 Motor is turning at 20°C (68°F) when battery voltage is 12 V 10.6 to 16.6 A


If the result is not as specified, replace the No. 2 cooling fan motor.


e.

Reconnect the No. 2 cooling fan motor connector.