After moving the shift lever to S, it is possible to switch the shift range between "1" (S1 range) and "6" (S6 range) using the transmission control switch.
Moving the shift lever to "+" once raises the shift range by one, and moving the shift lever to "-" once lowers the shift range by one.
Inspect the fuses for circuits related to this system before performing the following procedure.
| *a | Front view of wire harness connector
(to Transmission Control Switch) |
Disconnect the transmission control switch connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| G36-4 (IG) - Body ground | Ignition switch ON | 11 to 14 V |
| G36-4 (IG) - Body ground | Ignition switch off | Below 1 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the transmission control switch connector.
| *a | Front view of wire harness connector
(to Transmission Control Switch) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G36-2 (E) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the transmission control switch connector.
| *A | for LHD |
| *a | Component without harness connected
(Transmission Control Switch) |
for LHD:
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4 (IG) - 5 (S) | Shift lever in S, "+" or "-" | Below 1 Ω |
| 3 (SFTU) - 2 (E) | Shift lever held in "+" (Up-shift) | Below 1 Ω |
| 1 (SFTD) - 2 (E) | Shift lever held in "-" (Down-shift) | Below 1 Ω |
| 4 (IG) - 5 (S) | Shift lever not in S, "+" or "-" | 10 kΩ or higher |
| 3 (SFTU) - 2 (E) | Shift lever in S | 10 kΩ or higher |
| 1 (SFTD) - 2 (E) | Shift lever in S | 10 kΩ or higher |
| *A | for RHD |
| *a | Component without harness connected
(Transmission Control Switch) |
for RHD:
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4 (IG) - 5 (S) | Shift lever in M, "+" or "-" | Below 1 Ω |
| 1 (SFTU) - 2 (E) | Shift lever held in "+" (Up-shift) | Below 1 Ω |
| 3 (SFTD) - 2 (E) | Shift lever held in "-" (Down-shift) | Below 1 Ω |
| 4 (IG) - 5 (S) | Shift lever not in M, "+" or "-" | 10 kΩ or higher |
| 1 (SFTU) - 2 (E) | Shift lever in M | 10 kΩ or higher |
| 3 (SFTD) - 2 (E) | Shift lever in M | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to ECM) |
Disconnect the ECM connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A62-27 (S) - Body ground | ·
Ignition switch ON ·
Shift lever in S, "+" or "-" |
11 to 14 V |
| A62-27 (S) - Body ground | ·
Ignition switch ON ·
Shift lever not in S, "+" or "-" |
Below 1 V |
Turn the ignition switch off.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A62-42 (SFTU) - Body ground | Shift lever held in "+" (Up-shift) | Below 1 Ω |
| A62-43 (SFTD) - Body ground | Shift lever held in "-" (Down-shift) | Below 1 Ω |
| A62-42 (SFTU) - Body ground | Shift lever in S | 10 kΩ or higher |
| A62-43 (SFTD) - Body ground | Shift lever in S | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG