Home › General › SPECIFICATIONS › 2AD-FHV COOLING › 2012.12–2015.10
RM3090E _V1 General _009232 SPECIFICATIONS _0050469 2AD-FHV COOLING F

SPECIFICATIONS  2AD-FHV COOLING  SERVICE DATA  


COOLANT
Capacity Classification
w/o Combustion Type Power Heater: 7.3 liters (7.7 US qts, 6.4 Imp. qts)
w/ Combustion Type Power Heater: 7.7 liters (8.1 US qts, 6.8 Imp. qts)
Use only "TOYOTA Super Long Life Coolant", or similar high qualityethylene glycol based non-silicate, non-amine, non-nitrite, and nonboratecoolant with long-life hybrid organic acid technology (coolantwith long-life hybrid organic acid technology is a combination of lowphosphates and organic acids).

THERMOSTAT
Thermostat Valve opening temperature 80 to 84°C (176 to 183°F)
Standard valve lift 10 to 14mm (0.394 to 0.551 in.) or more at 95°C (203°F)

COOLING FAN MOTOR
Item Tester Connection Condition Specified Condition
Cooling fan motor A52 - 2 Standard Current
Battery voltage applied at 20°C (68°F)
10.6 to 16.6 A
No. 2 cooling fan motor A51 - 1 Standard Current
Battery voltage applied at 20°C (68°F)
10.6 to 16.6 A

RADIATOR
Reservoir cap Standard Judgment Criterion Standard value
(for brand-new cap)
93 to 123 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi)
Minimum standard value
(for used cap)
79 kPa (0.8 kgf/cm2, 11.4 psi)

COOLING FAN RELAY
Item Tester Connection Condition Specified Condition
No. 1 cooling fan relay 3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Battery voltage applied between terminals 1 and 2 Below 1Ω
No. 2 cooling fan relay 3 - 4 Battery voltage not applied between terminals 1 and 2 Below 1Ω
3 - 4 Battery voltage applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Battery voltage applied between terminals 1 and 2 Below 1Ω
No. 3 cooling fan relay 3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Battery voltage applied between terminals 1 and 2 Below 1Ω