The generator control ECU assembly monitors battery conditions. If the voltage drops below a certain value while the engine is running (not cranking), the generator control ECU assembly determines the battery is deteriorated and stores this DTC.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory |
|---|---|---|---|---|---|
| P1602 | Deterioration of Battery | Battery capacity is abnormally low for 10 seconds or more when the engine is running (not cranking)
(1 trip detection logic) |
·
Battery ·
Wire harness or connector ·
ALT-S/ICS fuse |
Does not come on | DTC stored |
Refer to System Diagram.
Click herePower Source / Network>2AR-FE BATTERY / CHARGING>CHARGING SYSTEM>SYSTEM DIAGRAM
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Check the charging system.
Click herePower Source / Network>2AR-FE BATTERY / CHARGING>CHARGING SYSTEM>ON-VEHICLE INSPECTION
| Result |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Generator Control ECU Assembly) |
Disconnect the A58 generator control ECU assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A58-5 (AM21) - Body ground | Always | 11 to 14 V |
| Result |
|---|
| OK |
| NG |
OK
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
NG