DTC SUMMARY

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P0441 Evaporative Emission Control System Incorrect Purge Flow One of the following conditions met:
·

Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure measured. Reference pressure is measured at start and at end of leak check.

If stabilized pressure higher than [second reference pressure x 0.2], ECM determines that purge VSV stuck open.

·

After EVAP leak check performed, purge VSV turned on (open), and atmospheric air introduced into EVAP system. Reference pressure is measured at start and at end of check.

If pressure does not return to near atmospheric pressure, ECM determines that purge VSV stuck closed.

·

While engine running, following conditions successively met:

·

Negative pressure not created in EVAP system when purge VSV turned on (open)

·

EVAP system pressure change less than 0.4 kPa(gauge) [3 mmHg(gauge)] when vent valve turned on (closed)

·

Atmospheric pressure change before and after purge flow monitor less than 0.1 kPa(gauge) [0.75 mmHg(gauge)]



·

Purge VSV

·

Purge line

·

Connector/wire harness (purge VSV - ECM)

·

ECM

·

Canister pump module

·

Canister (filter inside canister clogged)

·

Leak from EVAP system


Comes on DTC stored

DTC No. Monitoring Item Detection Timing Detection Logic
P0441 Purge VSV (Vacuum Switching Valve) stuck open While ignition switch off 2 trip
Purge VSV stuck closed While ignition switch off
Purge flow While engine running

DESCRIPTION

The description can be found in EVAP (Evaporative Emission) System.

Click hereEngine / Hybrid System>2AR-FE ENGINE CONTROL>SFI SYSTEM(w/ Canister Pump Module)>EVAP System

MONITOR DESCRIPTION

The 2 monitors, key-off and purge flow, are used to detect malfunctions relating to DTC P0441. The key-off monitor is initiated by the ECM internal timer, known as the soak timer, 5 hours after the ignition switch is turned off. The purge flow monitor runs while the engine is running.

1.

KEY-OFF MONITOR

5 hours* after the ignition switch is turned off, the electric leak detection pump creates negative pressure (vacuum) in the EVAP (Evaporative Emission) system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.

HINT:

*: If the engine coolant temperature is not below 35°C (95°F) 5 hours after the ignition switch is turned off, the monitor check starts 2 hours later. If it is still not below 35°C (95°F) 7 hours after the ignition switch is turned off, the monitor check starts 2.5 hours later.


Sequence Operation Description Duration
- ECM activation Activated by soak timer 5, 7 or 9.5 hours after ignition switch turned off. -
A Atmospheric pressure measurement Vent valve is turned off (vent) and EVAP system pressure is measured by ECM in order to register atmospheric pressure.
If pressure in EVAP system is not between 70 kPa(abs) and 110 kPa(abs) [525 mmHg(abs) and 825 mmHg(abs)], ECM cancels EVAP system monitor.
60 seconds
B First reference pressure measurement In order to determine reference pressure, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally. 360 seconds
C EVAP system pressure measurement Vent valve is turned on (closed) to shut EVAP system.
Negative pressure (vacuum) is created in EVAP system, and EVAP system pressure is then measured.
Write down measured value as it will be used in leak check.
If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
15 minutes*
D Purge VSV monitor Purge VSV opened and then EVAP system pressure is measured by ECM.
A large increase indicates normality.
10 seconds
E Second reference pressure measurement After second reference pressure measurement, leak check is performed by comparing first and second reference pressure measurements.
If stabilized system pressure is higher than second reference pressure, ECM determines that EVAP system leaking.
60 seconds
- Final check Atmospheric pressure is measured and then monitoring result is recorded by ECM. -

*: If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.

A112612C02
1.604,2.156 1.75,2.438 false 2.458,1.094 2.823,0.99 false 2.406,1.646 2.792,1.625 false 2.563,2.021 2.833,2.021 false 1.208,3.302 1.208,3.427 false 1.302,4.479 1.583,4.5 false 2.323,3.188 1.854,3.948 false 5.083,0.958 5.083,1.083 false 5.323,2.198 5.448,2.156 false 5.135,4.479 5.448,4.5 false 5.083,3.302 5.083,3.438 false 1.604,1.083 1.698,0.677 false 0.635,2.063 1.469,1.948 false 0.604,1.656 1.146,1.74 false 1.781,1.583 1.854,1.354 1.854,1.354 2.802,1.354 false 5.656,1.594 5.719,1.365 5.719,1.365 6.677,1.365 false 5.708,3.948 5.771,3.719 5.771,3.719 6.729,3.719 false 1.219,0.948 1.198,1.125 false 0.198,0.156 0.51,0.344 0.313,0.188 10 *a 0.229,2.719 0.594,2.906 0.365,0.188 10 *c 4.469,0.167 4.792,0.365 0.323,0.198 10 *b 3.542,3.625 3.792,3.813 0.25,0.188 10 *e 0.417,1.552 0.646,1.74 0.229,0.188 10 *7 4.469,2.698 4.792,2.885 0.323,0.188 10 *d 1.635,0.51 2.167,0.688 0.531,0.177 10 *9 2.854,0.917 3.49,1.094 0.635,0.177 10 *10 2.854,1.25 3.094,1.427 0.24,0.177 10 *3 2.854,1.552 3.24,1.729 0.385,0.177 10 *11 2.844,1.948 3.125,2.125 0.281,0.177 10 *12 0.469,2 0.698,2.208 0.229,0.208 10 *8 1.76,2.448 2.073,2.625 0.313,0.177 10 *5 1.135,3.458 1.427,3.635 0.292,0.177 10 *1 1.146,4.396 1.375,4.573 0.229,0.177 10 *6 2.333,3.063 3.094,3.24 0.76,0.177 10 *4 3.552,4.208 3.802,4.438 0.25,0.229 10 *f 5.01,1.104 5.302,1.281 0.292,0.177 10 *1 5.146,2.125 5.375,2.302 0.229,0.177 10 *6 5,3.458 5.229,3.635 0.229,0.177 10 *2 4.979,4.385 5.208,4.563 0.229,0.177 10 *6 6.75,3.646 7.031,3.823 0.281,0.177 10 *4 6.719,1.281 6.958,1.458 0.24,0.177 10 *3 1.115,1.135 1.406,1.313 0.292,0.177 10 *1
*1 Purge VSV: Off (Closed) *2 Purge VSV: On (Open)
*3 Vent Valve: Off (Vent) *4 Vent Valve: On (Closed)
*5 Leak Detection Pump: Off *6 Leak Detection Pump: On
*7 Reference Orifice (0.02 inch) *8 Canister Pressure Sensor
*9 Canister *10 Fuel Tank
*11 Canister Pump Module *12 Canister Filter
*a Operation A:
Atmospheric Pressure Measurement
*b Operation B, E:
Reference Pressure Measurement
*c Operation C:
EVAP System Pressure Measurement
*d Operation D:
Purge VSV Monitor
*e Atmospheric Pressure *f Negative Pressure


1.

Purge VSV stuck open

In operation C, the leak detection pump creates negative pressure (vacuum) in the EVAP (Evaporative Emission) system. The EVAP system pressure is then measured by the ECM using the canister pressure sensor. If the stabilized system pressure is higher than [second reference pressure x 0.2], the ECM interprets this as the purge VSV being stuck open. The ECM illuminates the MIL and stores the DTC (2 trip detection logic).

A283585E02
0.094,0.052 2.646,0.24 2.552,0.188 10 EVAP Pressure when Purge Stuck Open: 0.354,0.625 1.094,0.854 0.74,0.229 10 Purge VSV 0.385,1.083 1.125,1.313 0.74,0.229 10 Vent Valve 0.135,1.427 1.104,1.833 0.969,0.406 10 Leak Detection Pump 0.094,2 1.135,2.229 1.042,0.229 10 EVAP Pressure 0.198,2.323 0.75,2.583 0.552,0.26 10 Positive 0.188,2.615 0.75,2.917 0.563,0.302 10 Negative 0.104,3.083 1.073,3.479 0.969,0.396 10 First Reference Pressure 0.438,4.146 1.167,4.396 0.729,0.25 10 Sequence 0.146,4.396 1.167,4.677 1.021,0.281 10 Time (Seconds) 1.708,4.156 1.938,4.333 0.229,0.177 10 A 2.563,4.156 2.792,4.333 0.229,0.177 10 B 3.823,2.125 4.583,2.333 0.76,0.208 10 Malfunction 5.135,4.156 5.365,4.333 0.229,0.177 10 D 5.729,4.156 5.958,4.333 0.229,0.177 10 E 1.677,4.385 2,4.604 0.323,0.219 10 60 2.5,4.385 2.823,4.604 0.323,0.219 10 360 3.427,4.385 4.583,4.583 1.156,0.198 10 Within 15 minutes 5.104,4.375 5.427,4.594 0.323,0.219 10 10 5.708,4.375 5.917,4.583 0.208,0.208 10 60 3.771,3.271 4.083,3.5 0.313,0.229 10 OK 3.885,1.625 4.167,1.833 0.281,0.208 10 ON 3.906,1.115 4.25,1.333 0.344,0.219 10 ON 5.083,0.563 5.417,0.75 0.333,0.188 10 ON 6.188,0.417 6.917,0.656 0.729,0.24 10 ON: Open 6.188,0.677 7.083,0.906 0.896,0.229 10 OFF: Closed 6.198,0.969 7,1.146 0.802,0.177 10 ON: Closed 6.208,1.229 6.917,1.417 0.708,0.188 10 OFF: Vent 6.271,2.635 6.938,3.385 0.667,0.75 10 [Second Reference Pressure] x 0.2 3.875,4.156 4.104,4.333 0.229,0.177 10 C

2.

Purge VSV stuck closed

In operation D, the canister pressure sensor measures the EVAP (Evaporative Emission) system pressure. The pressure measurement for the purge VSV monitor begins when the purge VSV is turned on (open) after the EVAP leak check. When the measured pressure indicates an increase of 0.3 kPa(gauge) [2.25 mmHg(gauge)] or higher, the purge VSV is functioning normally. If the pressure does not increase, the ECM interprets this as the purge VSV being stuck closed, illuminates the MIL and stores the DTC (2 trip detection logic).

A283586E02
0.094,0.063 3.083,0.292 2.99,0.229 10 EVAP Pressure when Purge VSV Stuck Closed: 0.354,0.583 1.167,0.833 0.813,0.25 10 Purge VSV 0.396,1.042 1.167,1.25 0.771,0.208 10 Vent Valve 0.135,1.458 1.104,1.875 0.969,0.417 10 Leak Detection Pump 0.083,2.021 1.167,2.24 1.083,0.219 10 EVAP Pressure 0.208,2.354 0.75,2.583 0.542,0.229 10 Positive 0.198,2.677 0.833,2.917 0.635,0.24 10 Negative 0.115,3.073 1.094,3.469 0.979,0.396 10 First Reference Pressure 0.438,4.167 1.083,4.406 0.646,0.24 10 Sequence 0.135,4.448 1.167,4.667 1.031,0.219 10 Time (Seconds) 2.573,4.177 2.792,4.375 0.219,0.198 10 B 3.917,4.188 4.135,4.385 0.219,0.198 10 C 5.146,4.188 5.365,4.385 0.219,0.198 10 D 5.729,4.188 5.948,4.385 0.219,0.198 10 E 1.719,4.177 1.938,4.375 0.219,0.198 10 A 1.688,4.448 1.917,4.667 0.229,0.219 10 60 2.51,4.448 2.833,4.667 0.323,0.219 10 360 3.448,4.448 4.667,4.667 1.219,0.219 10 Within 15 minutes 5.708,4.438 6,4.667 0.292,0.229 10 60 5.115,4.438 5.333,4.667 0.219,0.229 10 10 4.354,2.063 4.677,2.313 0.323,0.25 10 OK 3.865,1.646 4.188,1.896 0.323,0.25 10 ON 3.865,1.135 4.188,1.385 0.323,0.25 10 ON 5.073,0.594 5.396,0.844 0.323,0.25 10 ON 6.271,0.448 7,0.646 0.729,0.198 10 ON: Open 6.281,0.719 7.125,0.948 0.844,0.229 10 OFF: Closed 6.271,1.01 7.083,1.219 0.813,0.208 10 ON: Closed 6.281,1.281 7,1.51 0.719,0.229 10 OFF: Vent 3.885,2.885 4.667,3.083 0.781,0.198 10 Malfunction


2.

PURGE FLOW MONITOR

The purge flow monitor consists of 2 monitors. The 1st monitor is conducted every time and the 2nd monitor is activated if necessary.

A283587E04
0.083,0.063 2.833,0.302 2.75,0.24 10 EVAP Pressure During Purge Flow Monitor: 2.031,0.708 2.833,0.917 0.802,0.208 10 Purge VSV 2.063,1.063 2.833,1.25 0.771,0.188 10 Vent Valve 1.75,1.427 2.833,1.667 1.083,0.24 10 EVAP Pressure 3.583,0.646 4,0.833 0.417,0.188 10 Open 3.625,1.021 4.5,1.25 0.875,0.229 10 ON (Closed) 4.427,1.271 5.26,1.469 0.833,0.198 10 Malfunction 4.427,1.573 6.833,1.813 2.406,0.24 10 0.1 kPa(gauge) [0.75 mmHg(gauge)] 4.427,1.958 7.073,2.188 2.646,0.229 10 0.4 kPa(gauge) [3 mmHg(gauge)] 2.813,2.417 4.333,2.667 1.521,0.25 10 1st Monitor 2nd Monitor 3.229,1.781 3.5,2 0.271,0.219 10 OK 4.125,2.146 4.417,2.333 0.292,0.188 10 OK


·

The 1st monitor

While the engine is running and the purge VSV is on (open), the ECM monitors the purge flow by measuring the EVAP pressure change. If negative pressure is not created, the ECM begins the 2nd monitor.

·

The 2nd monitor

The vent valve is turned on (closed) and the EVAP pressure is then measured. If the variation in the pressure is less than 0.4 kPa(gauge) [3 mmHg(gauge)], the ECM interprets this as the purge VSV being stuck closed, illuminates the MIL and stores DTC P0441 (2 trip detection logic).


Atmospheric pressure check:

In order to ensure reliable malfunction detection, the variation between the atmospheric pressures, before and after conduction of the purge flow monitor, is measured by the ECM.

MONITOR STRATEGY

Required Sensors/Components Purge VSV
Canister pump module
Frequency of Operation Once per driving cycle

CONFIRMATION DRIVING PATTERN

1.

Connect the GTS to the DLC3.

2.

Turn the ignition switch to ON and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the ignition switch off and wait for at least 30 seconds.

5.

Turn the ignition switch to ON and turn the GTS on.

6.

Start the engine and wait 15 minutes or more.

7.

Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.

8.

Read the pending DTCs.

HINT:
·

If a pending DTC is output, the system is malfunctioning.

·

If a pending DTC is not output, perform the following procedure.



9.

Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.

10.

Input the DTC: P0441.

11.

Check the DTC judgment result.

GTS Display Description
NORMAL
·

DTC judgment completed

·

System normal


ABNORMAL
·

DTC judgment completed

·

System abnormal


INCOMPLETE
·

DTC judgment not completed

·

You should perform driving pattern after confirming DTC enabling conditions


N/A
·

Unable to perform DTC judgment

·

Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit



HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform the following procedure.



NOTICE:
·

The Evaporative System Check (Automatic Mode) consists of 6 steps performed automatically by the GTS. It takes a maximum of approximately 24 minutes.

·

Do not perform the Evaporative System Check when the fuel tank is higher than 90% full because the cut-off valve may be closed, making the fuel tank leak check unavailable.

·

Do not run the engine during this operation.

·

When the temperature of the fuel is 35°C (95°F) or higher, a large amount of vapor forms and any check results become inaccurate. When performing the Evaporative System Check, keep the fuel temperature below 35°C (95°F).



12.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

13.

Turn the ignition switch off and wait for at least 30 seconds.

14.

Turn the ignition switch to ON and turn the GTS on.

15.

Enter the following menus: Powertrain / Engine and ECT / Utility / Evaporative System Check / Automatic Mode.

16.

After the Evaporative System Check is completed, check for All Readiness by entering the following menus: Powertrain / Engine and ECT / Utility / All Readiness.

17.

Input the DTC: P0441.

18.

Check the DTC judgment result.

GTS Display Description
NORMAL
·

DTC judgment completed

·

System normal


ABNORMAL
·

DTC judgment completed

·

System abnormal


INCOMPLETE
·

DTC judgment not completed

·

Perform driving pattern after confirming DTC enabling conditions


N/A
·

Unable to perform DTC judgment

·

Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit



HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.