16331A
1.INSPECT THERMOSTAT
The valve opening temperature is inscribed on the thermostat.
| *a | for Type A |
| *b | for Type B |
Check that the valve is fully closed when the thermostat is at low temperatures (below 75°C (167°F)).
If it is not fully closed, replace the thermostat.
Immerse the thermostat in water and then gradually heat the water.
Check the valve opening temperature of the thermostat.
78 to 82°C (172 to 180°F)
If the valve opening temperature is not as specified, replace the thermostat.
| *a | for Type A |
| *b | for Type B |
| *c | Valve Lift |
Check the valve lift.
| Item | Condition | Specified Condition |
|---|---|---|
| for Type A | 93°C (199°F) | 10 mm (0.394 in.) or more |
| for Type B | 95°C (203°F) | 10 to 14 mm (0.394 to 0.551 in.) |
If the valve lift is not as specified, replace the thermostat.