1.INSPECT GLOW PLUG RELAY ASSEMBLY
Disconnect the glow plug relay connector.
Detach the clamp and remove the glow plug relay.
Check the resistance.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | Battery voltage not applied to terminals 3 and 4 | 10 kΩ or higher |
| Battery voltage applied to terminals 3 and 4 | Below 1 Ω |
If the result is not as specified, replace the glow plug relay assembly.
28300
2.INSPECT STRTER RELAY (ST)
Check the resistance.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage not applied to terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied to terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the ST NO. 1 relay.