Each unit of the navigation system connected to the AVC-LAN (communication bus) transfers the switch signals using the AVC-LAN.
If a short to +B or short to ground occurs in the AVC-LAN, the navigation system will not function normally because communication is not possible.
The radio and display receiver assembly is the master unit.
Check that the wire harness is properly installed and does not have any sharp bends, pinching or loose connections.
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
| *A | w/ Panoramic View Monitor System |
| *B | for 11 Speakers |
| *a | Component without harness connected (Radio and Display Receiver Assembly) |
Remove the radio and display receiver assembly with the connector(s) still connected.
Click hereAudio / Visual / Telematics>AUDIO / VIDEO>RADIO RECEIVER>REMOVAL
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 7 (TX3+) - 8 (TX3-) | Always | 60 to 80 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 7 (TX1+) - 8 (TX1-) | Always | 60 to 80 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
*1: for 11 Speakers
*2: w/ Panoramic View Monitor System
Disconnect the G143 and G158 radio and display receiver assembly connector.
Disconnect the M32 stereo component amplifier assembly connector.*1
Disconnect the a2 parking assist ECU connector.*2
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M32-8 (TX+) - G143-7 (TX1+) | Always | Below 1 Ω |
| M32-7 (TX-) - G143-8 (TX1-) | Always | Below 1 Ω |
| M32-8 (TX+) - Body ground | Always | 10 kΩ or higher |
| M32-7 (TX-) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| a2-10 (TX+) - G158-7 (TX3+) | Always | Below 1 Ω |
| a2-9 (TX-) - G158-8 (TX3-) | Always | Below 1 Ω |
| a2-10 (TX+) - Body ground | Always | 10 kΩ or higher |
| a2-9 (TX-) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect and reconnect each slave unit one by one until the master unit returns to normal operation.
Check all slave units.
If disconnecting a slave unit causes the master unit to return to normal operation, the slave unit is defective and should be replaced.
Master unit returns to normal operation.
| Proceed to |
|---|
| OK |
| NG |
OK
NG