Home › Engine / Hybrid System › CRUISE CONTROL › SPEED LIMITER SYSTEM › from 2015.10
RM3090E _51 Engine / Hybrid System _008749 CRUISE CONTROL _0226926 SPEED LIMITER SYSTEM U

CRUISE CONTROL  SPEED LIMITER SYSTEM  TERMINALS OF ECM  


CHECK ECM (for 2WW)


A318632E04
2.563,0.573 3.052,0.875 0.49,0.302 5.365,0.573 5.854,0.865 0.49,0.292 2.656,0.646 3.042,0.844 0.385,0.198 10 false B112 5.479,0.635 5.802,0.833 0.323,0.198 10 false A62

HINT:

The standard voltage between each pair of the ECM terminals is shown in the table below. The appropriate conditions for checking each pair of the terminals are also indicated.

The result of checks should be compared with the standard voltage for that pair of terminals, and displayed in the "Specified Condition" column.

The illustration above can be used as a reference to identify the ECM terminal locations.


for 2WW:
Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
A62-4 (E1) - Body ground W-B - Body ground Ground Always Below 1 Ω
A62-15 (BATT) - A62-4 (E1) W - W-B Power source circuit Always 11 to 14 V
A62-37 (IGSW) - A62-4 (E1) B - W-B IG power source circuit Ignition switch ON 11 to 14 V
Ignition switch off Below 1 V
A62-49 (ASLM) - A62-42 (ECCS) P - BR Speed limiter switch signal Speed limiter switch on Below 1 Ω
Speed limiter switch off 10 kΩ or higher


CHECK ECM (for 3ZR-FAE)


A342925E06
2.333,0.448 2.729,0.698 0.396,0.25 5.885,0.448 6.281,0.698 0.396,0.25 5.948,0.49 6.406,0.688 0.458,0.198 10 false A62 2.406,0.49 2.865,0.688 0.458,0.198 10 false B93

HINT:

The standard normal voltage between each pair of the ECM terminals is shown in the table below. The appropriate conditions for checking each pair of the terminals are also indicated. The result of checks should be compared with the standard normal voltage for that pair of the terminals, which is displayed in the Specified Condition column. The illustration above can be used as a reference to identify the ECM terminal locations.


for 3ZR-FAE:
Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
A62-1 (BATT) - B93-59 (E1) W - BR Power source circuit Always 11 to 14 V
A62-6 (IGSW) - B93-59 (E1) B - BR Ignition switch signal Ignition switch ON 11 to 14 V
A62-20 (ASLM) - A62-35 (ECCS) P - BR Speed limiter switch signal Speed limiter switch on Below 1 Ω
Speed limiter switch off 10 kΩ or higher
B93-59 (E1) - Body ground BR - Body ground Ground Always Below 1 Ω