The ECM calculates an appropriate cooling fan speed based on the engine coolant temperature, air conditioning switch condition, refrigerant pressure, engine speed and vehicle speed, and sends the signals to the cooling fan ECUs to regulate the cooling fans. The cooling fan ECUs control each cooling fan speed based on the duty ratio signal sent from the ECM. By basing its control on the operating conditions, the ECM can control the fan speed optimally using the cooling fan ECUs, achieving both high cooling performance and quietness.
Refer to the System Diagram.
Click hereEngine / Hybrid System>2AD-FTV COOLING>COOLING FAN SYSTEM(w/ Towing Package)>SYSTEM DIAGRAM
Inspect the fuses for circuits related to this system before performing the following procedure.
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Engine / Active Test / Control the Engine Cooling Fan Duty Ratio.
| Tester Display |
|---|
| Control the Engine Cooling Fan Duty Ratio |
Check the operation of the cooling fans while operating them using the GTS.
| Tester Operation | Fan Operation |
|---|---|
| 100% | Cooling fans operate |
| 0% | Cooling fans stop |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (Fan does not operate) | B |
| NG (No. 2 fan does not operate) | C |
| NG (Fan does not stop) | D |
| NG (No. 2 fan does not stop) | E |
A
Click hereEngine / Hybrid System>2AD-FTV COOLING>COOLING FAN SYSTEM(w/ Towing Package)>PROBLEM SYMPTOMS TABLE
B
C
D
E
Disconnect the ECM connector.
Turn the engine switch on (IG).
Check the operation of the cooling fan.
The cooling fan operates.
| Proceed to |
|---|
| OK |
| NG |
OK
Click here ENGINE CONTROL (2AD-FTV) > ECM > REMOVAL
NG
Inspect the cooling fan motor.
Click hereEngine / Hybrid System>2AD-FTV COOLING>COOLING FAN MOTOR>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Cooling Fan ECU) |
Disconnect the cooling fan ECU connector.
Turn the engine switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A93-1 (+B1) - A93-3 (E1) | Engine switch on (IG) | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cooling fan ECU connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A93-2 (SI) or A61-49 (RFC) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cooling fan ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A93-3 (E1) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the FAN NO. 1 relay.
Click hereEngine / Hybrid System>2AD-FTV COOLING>RELAY>ON-VEHICLE INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 2 engine room relay block and junction block assembly |
| *2 | FAN NO. 1 Relay |
Remove the FAN NO. 1 relay from the No. 2 engine room relay block and junction block assembly.
Turn the engine switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 (FAN NO. 1 relay) - Body ground | Always | 11 to 14 V |
| 1 (FAN NO. 1 relay) - Body ground | Engine switch on (IG) | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the FAN NO. 1 relay from the No. 2 engine room relay block and junction block assembly.
Disconnect the cooling fan ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 5 (FAN NO. 1 relay) - A93-1 (+B1) | Always | Below 1 Ω |
| 5 (FAN NO. 1 relay) or A93-1 (+B1) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the ECM connector.
Turn the engine switch on (IG).
Check the operation of the No. 2 cooling fan.
The No. 2 cooling fan operates.
| Proceed to |
|---|
| OK |
| NG |
OK
Click here ENGINE CONTROL (2AD-FTV) > ECM > REMOVAL
NG
Inspect the No. 2 cooling fan motor.
Click hereEngine / Hybrid System>2AD-FTV COOLING>COOLING FAN MOTOR>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to No. 2 Cooling Fan ECU) |
Disconnect the No. 2 cooling fan ECU connector.
Turn the engine switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A99-1 (+B2) - A99-3 (E2) | Engine switch on (IG) | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the No. 2 cooling fan ECU connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A99-2 (SI2) or A61-48 (RFC2) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the No. 2 cooling fan ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A99-3 (E2) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the FAN NO. 2 relay.
Click hereEngine / Hybrid System>2AD-FTV COOLING>RELAY>ON-VEHICLE INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 2 engine room relay block and junction block assembly |
| *2 | FAN NO. 2 Relay |
Remove the FAN NO. 2 relay from the No. 2 engine room relay block and junction block assembly.
Turn the engine switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 (FAN NO. 2 relay) - Body ground | Always | 11 to 14 V |
| 1 (FAN NO. 2 relay) - Body ground | Engine switch on (IG) | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the FAN NO. 2 relay from the No. 2 engine room relay block and junction block assembly.
Disconnect the No. 2 cooling fan ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 5 (FAN NO. 2 relay) - A99-1 (+B2) | Always | Below 1 Ω |
| 5 (FAN NO. 2 relay) or A99-1 (+B2) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cooling fan ECU connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A93-2 (SI) - A61-49 (RFC) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cooling fan motor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z1-1 (-) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the No. 2 cooling fan ECU connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A99-2 (SI2) - A61-48 (RFC2) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the No. 2 cooling fan motor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z9-1 (-) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG