Home › General › SPECIFICATIONS › 2WW COOLING › from 2015.10
RM3090E _V1 General _009232 SPECIFICATIONS _0208137 2WW COOLING F

SPECIFICATIONS  2WW COOLING  SERVICE DATA  


Coolant
Item Capacity Classification
w/o Combustion Type Power Heater 7.0 liters (7.4 US qts, 6.2 Imp. qts) Toyota recommends the use of approved "Toyota Premium Long Life Coolant for 2WW engines" or equivalent.
w/ Combustion Type Power Heater 7.3 liters (7.7 US qts, 6.4 Imp. qts)

Thermostat
Condition Specified Condition
Standard valve opening temperature 100 °C (212 °F)

Cooling Fan Motor
Item Condition Specified Condition
Cooling fan motor Battery voltage applied at 20°C (68°F) 12.2 to 15.7 A
No. 2 cooling fan motor Battery voltage applied at 20°C (68°F) 12.2 to 15.7 A

Radiator
Item Condition Specified Condition
Reservoir Cap Standard pressure
(for brand-new reservoir cap)
126 to 143 kPa (1.3 to 1.5 kgf/cm2, 18 to 21 psi)
Minimum standard value
(for used cap)
101 kPa (1.0 kgf/cm2, 15 psi)