RM3090E
_V1
General
_009232
SPECIFICATIONS
_0208137
2WW COOLING
F
SPECIFICATIONS 2WW COOLING SERVICE DATA
Coolant
| Item
|
Capacity
|
Classification
|
| w/o Combustion Type Power Heater
|
7.0 liters (7.4 US qts, 6.2 Imp. qts)
|
Toyota recommends the use of approved "Toyota Premium Long Life Coolant for 2WW engines" or equivalent.
|
| w/ Combustion Type Power Heater
|
7.3 liters (7.7 US qts, 6.4 Imp. qts)
|
Thermostat
| Condition
|
Specified Condition
|
| Standard valve opening temperature
|
100 °C (212 °F)
|
Cooling Fan Motor
| Item
|
Condition
|
Specified Condition
|
| Cooling fan motor
|
Battery voltage applied at 20°C (68°F)
|
12.2 to 15.7 A
|
| No. 2 cooling fan motor
|
Battery voltage applied at 20°C (68°F)
|
12.2 to 15.7 A
|
Radiator
| Item
|
Condition
|
Specified Condition
|
| Reservoir Cap
|
Standard pressure
(for brand-new reservoir cap)
|
126 to 143 kPa (1.3 to 1.5 kgf/cm2, 18 to 21 psi)
|
Minimum standard value
(for used cap)
|
101 kPa (1.0 kgf/cm2, 15 psi)
|